EUROSTER 11, 11C USER MANUAL
MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND

1. INTRODUCTION

Carefully study this user manual to learn how to correctly operate the EUROSTER 11/11C
central heating (CH) pump controller.

2. FIELD OF APPLICATION

EUROSTER 11/11C is an electronic controller used to automatically turn ON/OFF CH system
circulation pump depending on CH system water temperature. The pump may circulate water
through a system heated by a coal- or gas-fired boiler. Water temperature is sensed by a
sensor located at the CH system inlet.
The controller will also turn the pump OFF as soon as coal-fired boiler flame is put out. Water
should not be circulated unless it is heated by the boiler since chimney air draft cools down the
boiler water much faster than the radiator water.
Controller is equipped with a knob used to preset optimum CH system water temperature
(most often around 40ºC). If the controller cooperates with a gas-fired boiler, its set
point MUST BE LOWER than the boiler thermostat set point. Set the controller set
point higher than the dew point in order to prevent boiler sweat during the process
of heating the water up.
The EUROSTER 11/11C controller features the ANTY STOP
function that prevents idle pump rotors and valves against
seizing. Once the heating season is over, every 14 days the
function automatically turns ON the pumps and the valves for
30 seconds. To that end the controller must be left powered up.

3. VISIBLE CONTROLLER ELEMENTS

EUROSTER 11/11C
CENTRAL HEATING PUMP CONTROLLER
1. Mains switch
2. 230 VAC~ mains input
3. 230 VAC~ power supply to pump
4. Input for the boiler temperature sensor
cable
5. Temperature preset knob
6. Controller turned on green LED
7. Pump turned on red LED
8. Continuous operation switch
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 11 and is the answer not in the manual?

Questions and answers

Summary of Contents for EUROSTER 11

  • Page 1 CENTRAL HEATING PUMP CONTROLLER MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND 1. INTRODUCTION Carefully study this user manual to learn how to correctly operate the EUROSTER 11/11C central heating (CH) pump controller. 2. FIELD OF APPLICATION EUROSTER 11/11C is an electronic controller used to automatically turn ON/OFF CH system circulation pump depending on CH system water temperature.
  • Page 2 7. MANUAL OPERATION Manual pump switch of the EUROSTER E11/11C controller may be useful e.g. to help de- aerate the system or in case of a failure of the temperature sensor. 1. Turn the continuous operation switch (8 in section 3) into the “I” position (red LED goes ON).
  • Page 3 Otherwsie (the LED goes OFF but the pump does not stop) check the connections. 9. COMPATIBILITY WITH STANDARDS/CERTIFICATES The EUROSTER 11/11C controller meets all requirements of the EMC and the LVD EU Directives. The CE Conformity Declaration is available on the http://www.euroster.com.pl Internet webpage.
  • Page 4 EUROSTER 11, 11C USER MANUAL ELECTRONIC WASTE MANAGEMENT INFORMATION We made every effort to get as a long controller lifetime as possible. However, the device is subject to natural tear and wear. We ask you to have a controller that will not meet your requirements any more brought in to an electronic waste management facility.

This manual is also suitable for:

11c

Table of Contents