Annovi Reverberi RSV Series Operating Instructions And Parts Manual

Annovi Reverberi RSV Series Operating Instructions And Parts Manual

Plunger pumps

Advertisement

Operating Instructions and Parts Manual
Operating Instructions and Parts Manual
Plunger Pumps
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
Description
Plunger Pumps are designed for a wide variety of high
pressure washing applications. They are constructed
with die-cast bodies and feature a brass head. Internal
components include coated ceramic plungers for long life
and durability. Precision cast cooling fins are anodized for
maximum heat dissipation. Oversized needle bearings on the
drive side, and ball on the non-drive side together with the
precision supports assure positive alignment and centering
in relation to the crankcase. Valve cages of special designed
Ultra-Form provide positive seating and extended life. One-
piece connecting rods are special alloy aluminum, bronze
rods over 4,000 psi units, oversized for strength and load
disbursement. These pumps are designed for gasoline driven
systems.
RSV 3400 rpm D Version - 3/4"
Model
RSV2.5G25D-F25
RSV3G25D-F25
RSV 3400 rpm D Version - 1"
Model
RSV3G35D-F40
RSV3.5G35D-F40
RSV4G40D-F40
RSV4G40D-F40
Form RSV-OM 0607
Max GPM
Max PSI
2.5
2500
3
2500
Max GPM
Max PSI
3
3500
3.5
3500
4
3000
4
4000
RSV Series Pumps
RSV Series Pumps
Figure 1
Hollow Shaft
Figure 2
Hollow Shaft
NORTH
AMERICA
First Choice When Quality Matters
High Performance Pumps

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RSV Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Annovi Reverberi RSV Series

  • Page 1 RSV Series Pumps Operating Instructions and Parts Manual RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
  • Page 2 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps NORTH AMERICA First Choice When Quality Matters...
  • Page 3: General Safety Information

    RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Formulas Conversions Nozzles: Gallons x 3.785412 = Liters Impact Force (lbs.) = .0526 x GPM x √PSI Gallons x 128 = Oz. PSI x .06896 = Bar Nozzle # = GPM x 4000 √...
  • Page 4: Installation

    RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Installation General Safety Information (continued) Direct Drive Gasoline Pumps Maximum water temperature is 1. Install the shaft key into the 140°F. keyway and apply All positive displacement plunger a light coating of...
  • Page 5 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Installation (continued) down on the pliers, the valve will lift out. (See through the pump. Figure 6) Flush the pump with fresh water Use a small probe to before the next use.
  • Page 6 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Service Pumps (continued) high-pressure seal and head ring out of the Disassembly: head. (See Figure 15) First remove the eight The low-pressure seal 5mm head bolts. (See is located in the brass...
  • Page 7 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Service Pumps (continued) head as a base, push down on the pliers, the valve will lift out. seal (Make sure it is squarely seated). Use a small probe to move the...
  • Page 8 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Service Pumps (continued) Unloader Removal: Oil Change Tools required: 3/8” rachet, 22mm deep well socket, crescent wrench, small Change oil after first 50 hours of use. hammer, 6mm x approximately 8mm or Then every 500 hours.
  • Page 9 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Service Pumps (continued) Unloader Adjusting Instructions Follow these easy steps to adjust the pressure: Loosen nut (pos. #3) with 10mm wrench. Turn brass (pos. #4) clockwise until it stops. Start pump, watch pressure gauge and turn (pos.
  • Page 10: Troubleshooting

    RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Troubleshooting Symptom Possible Cause(s) Corrective Action Oil leak between Worn rod oil seals Replace crankcase piston rod crankcase and pump- seals ing section Frequent or prema- 1 Cracked, damaged or worn...
  • Page 11 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Troubleshooting (cont.) Symptom Possible Cause(s) Corrective Action Low pressure (cont.) 3 Air leak in inlet plumbing 3 Disassemble, reseal and reas- semble 4 Relief valve stuck, partially 4 Clean and adjust relief valve;...
  • Page 12: Repair Kits

    RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps 3400 "D" VERSION 3/4” Ø TYPE F25 "D" VERSION 1” Ø Valves Pistons Kit 2186 Kit 2187 TYPE F40 Repair Kits Valves Pistons Kit 2186 Kit 2187 Valves Pistons Oil Seals...
  • Page 13 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Pos. Code Description Qty. Pos. Code Description Qty. 1980300 1981570 Piston guide 2760420 Grub screw 770260 O-Ring M6x12 23.52x1.78 Ø 1980540 Unloader knob 1260440 Gasket 1980220 Spring plate 640070 O-Ring 13.95x2.62...
  • Page 14 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Notes NORTH AMERICA First Choice When Quality Matters...
  • Page 15 RSV Series Pumps Operating Instructions and Parts Manual Plunger Pumps Notes NORTH AMERICA First Choice When Quality Matters...
  • Page 16: Torque Specifications

    442/(37) imited arranty Annovi Reverberi (A.R.) Cam Shaft Plunger Pumps are warranted for a period of five years and Axial Radial Pumps are warranted for a period of one year to the original purchaser. Electric Pressure Washers are warranted for a period of one year to the original purchaser. This is from the date shipped from factory or U.S.

Table of Contents

Save PDF