DIAGNOSTIC STATUS CODES
TRANSISTOR PUMP CONTROL
PUMP STATUS
DESCRIPTION OF STATUS
CODE
Key switch is open for more than 8
-103
seconds while the SL3 switch is closed
MEMORY RECALL
CORRECTIVE
YES
SYMPTOM:
Circuits valid
•=
for
Pump
Controller
POSSIBLE CAUSE:
•=
Replace SL3 switch.
PUMP STATUS
DESCRIPTION OF STATUS
CODE
Key switch is open for more than 8
-104
seconds while the SL4 switch is closed
MEMORY RECALL
CORRECTIVE
YES
SYMPTOM:
Circuits valid
•=
for
Pump
Controller
POSSIBLE CAUSE:
•=
Replace SL4 switch.
ACTIONS
Speed limit 3 is
closed and vehicle
will not exceed the
speed indicated by
SL3.
Defective SL3
switch.
ACTIONS
Speed limit 4 is
closed and vehicle
will not exceed the
speed indicated by
SL4.
Defective SL4
switch.
CAUSE OF STATUS INDICATION
This status code will be displayed when SL3 is
closed with the key switch off.
TROUBLE-SHOOTING DIAGRAM
FU5
KEY SWITCH
1A
FU6
P1
P18
P17
P16
P15
P9 P8
P11
LINE
FU1
+
POS
A1
POWER CONNECTIONS
-
NEG
A2
1A
CAUSE OF STATUS INDICATION
This status code will be displayed when SL4 is
closed with key switch off.
TROUBLE-SHOOTING DIAGRAM
FU5
KEY SWITCH
1A
FU6
P1
P18
P17
P16
P15
P9 P8
P11
LINE
FU1
+
POS
A1
POWER CONNECTIONS
-
NEG
A2
1A
TO
TRACTION
P10 - BDI
L
P2
P10
P6 P5
P4 P3
P14
P13
P21
P20
TO TRACTION
CARD
TO
TRACTION
P10 - BDI
L
P2
P10
P6 P5
P4 P3
P14
P13
P21
P20
TO TRACTION
CARD
Page 40
+5V FROM
TRACTION PY10
PY10
PY12
P19
P12
PY7
PY11
ACC POT
+5V FROM
TRACTION PY10
PY10
PY12
P19
P12
PY7
PY11
ACC POT
October 1998

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic3645sp4r400u2

Table of Contents