DESCRIPTION
AD 800-AM is an acoustic glass break detector giving an alarm
when glass is smashed at intruder attempts through windows,
doors and glazed walls.
The detector is based on advanced microcontroller technology
and programmed to take a lot of relevant acoustic factors into
account: the Digital Room Compensation (DRC). This makes the
detector able to distinguish between a true glass break and other
irrelevant sounds.
The detector is for indoor use. The coverage distance is 1–9 m.
The coverage angle is 165º, which means that one detector can
protect several windows in the same room. The detector can be
mounted in the ceiling or on a wall with a free "line of sight" to
the window being protected.
AD 800-AM is equipped with an AM function, a separate relay,
which gives an alarm at sabotage of microphone.
AD 800-AM is certified according to EN 50131-2-7-1:2012, secu-
rity grade 3.
Coverage area in the acoustic room Zone 1-3
CONNECTION TO A 24-HOUR LOOP
The detector is constructed for continuous supervision and is ex-
tra resistant to different acoustic disturbances. It will function
well in most environments. However in rooms with very high
rates of disturbances as in industrial workshops and gyms, it is
recommended to test the detector for 3-4 weeks before deciding
to use it continuously. In rare cases a combination of random
sounds can trigger an alarm.
© 2016 Alarmtech –
www.alarmtech.se
SIGNALLED EVENTS
Detector has two relays and one micro-switch to signal detected
and processed events to control panel in prioritised order as fol-
lowing signals:
Base
Glass break – signalled by INTRUSION relay
Low power supply voltage or self-test fail – signalled by
FAULT relay
Masking – signalled by INTRUSION and FAULT relay
Sabotage is signaled independently by TAMPER micro-switch.
LED
Event
No stimulus
Intrusion
Masking
Low Supply Voltage
Local Self-Test Fail
Tamper
SPECIAL TOOLS
In most rooms (e.g. offices) no special tools are required during
the installation. In rooms with complicated acoustics it is recom-
mended to use the ADT 700 tester. ADT 700 can also be used for
function test and annual service.
OPENING THE DETECTOR
Slide the lock cover up
Loosen the screw
Pull cover to open
MOUNTING INSTRUCTIONS
Detector should be installed on a ceiling or on a wall oppo-
site to the glass to be protected
Clear "line-of- sight" between the "microphone" of the de-
tector and the glass is required
Distance between the glass and the detector should be 1-9 m
Detector should be installed min. 50 cm from a corner
Detector should be installed min. 1 m over the floor
Detector should be installed min. 30 cm from the ceiling (at
wall mounting)
Detector should be installed on a flat surface, which is free
from objects in a radius of 50 cm from the detector
Detector should not be installed close to air vents or big
sound reflecting obstacles
Never mount the detector in the corners
1 / 4
Acoustic Glass Break Detector
with Antimasking
Signal sent by relay or micro-switch
INTRUSION
FAULT
Closed
Closed
OPEN
Closed
OPEN
OPEN
Closed
OPEN
Closed
OPEN
Closed
Closed
min. 0.5 m
Location for wall or ceiling mount
AD800-AM manual nh1643a_en
AD 800-AM
TAMPER
Closed
Closed
Closed
Closed
Closed
OPEN
min. 0.3 m
min. 0.5 m
min.
1 m