Download Print this page
Alarmtech AD 700 Installation Manual

Alarmtech AD 700 Installation Manual

Acoustic glass break detector

Advertisement

Quick Links

Detectors
Datasheet and installation manual
DESCRIPTION
AD 700 is an acoustic glass break detector giving an alarm
when glass is smashed at intruder attempts through windows,
doors and glazed walls.
The detector is based on advanced microcontroller
technology and programmed to take a lot of relevant acoustic
factors into account: the Digital Room Compensation (DRC).
This makes the detector able to distinguish between a true
glass break and other irrelevant sounds.
The detector is for indoor use.
The coverage distance is 1–9 m. The coverage angle is 165º,
which means that one detector can protect several windows
in the same room. The detector can be mounted in the ceiling
or on a wall with a free "line of sight" to the window being
protected.
AD 700 is certified according to EN 50131-2-7-1:2012, secu-
rity grade 2.
Coverage area in the acoustic room Zone 1-3
CONNECTION TO A 24-HOUR LOOP
The detector is constructed for continuous supervision and is
extra resistant to different acoustic disturbances. It will func-
tion well in most environments. However in rooms with very
high rates of disturbances as in industrial workshops and
gyms, it is recommended to test the detector for 3-4 weeks
before deciding to use it continuously. In rare cases a combi-
nation of random sounds can trigger an alarm.
SPECIAL TOOLS
In most rooms (e.g. offices) no special tools are required dur-
ing the installation. In rooms with complicated acoustics it is
recommended to use the ADT 700 tester. ADT 700 can also be
used for function test and annual service.
© 2016 Alarmtech
Acoustic Glass Break Detector
MOUNTING INSTRUCTIONS
 Detector should be installed on a ceiling or on a wall
opposite to the glass to be protected
 Clear "line-of- sight" between the "microphone" of the
detector and the glass is required
 Distance between the glass and the detector should be 1-
9 m
 Detector should be installed min. 50 cm from a corner
 Detector should be installed min. 1 m over the floor
 Detector should be installed min. 30 cm from the ceiling
(at wall mounting)
 Detector should be installed on a flat surface, which is free
from objects in a radius of 50 cm from the detector
 Detector should not be installed close to air vents or big
sound reflecting obstacles
 Never mount the detector in the corners
Location for wall or ceiling mount
INSTALLATION
1. Choose the best mounting position on the wall or ceiling.
2. Loosen the cover screw and remove the cover
3. Use the bottom part as a template and mark the place of
the holes of with a pen
4. Use a 2.5 mm drill for the self-tapping screws provided. If
necessary, use wall anchors
5. If necessary, cut out the marked "knockout hole" on the
back of the base with a pair of tongs
6. Pull the wiring cable through the "knockout hole" in the
bottom plate
7. Connect the wires to the screw terminals
Pin Marking Function
10
Sp
9
Sab
8
Sab
7
Sp
6
NC
5
C
4
D/N
3
AIS
2
+
1
-
The terminals can be connected to the sabotage loop or the
alarm loop (at your own choice).
1 / 4
AD 700
min. 0.3 m
min. 0.5 m
min. 0.5 m
min.
1 m
Spare terminal
Tamper switch output
Tamper switch output
Spare terminal
Relay output Normally Closed
Relay output Common
Day and Night control of LED
Alarm Information System
Plus 9 to 15 V DC
Ground
AD700 manual 1643en

Advertisement

loading
Need help?

Need help?

Do you have a question about the AD 700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alarmtech AD 700

  • Page 1  Detector should not be installed close to air vents or big DESCRIPTION sound reflecting obstacles AD 700 is an acoustic glass break detector giving an alarm  Never mount the detector in the corners when glass is smashed at intruder attempts through windows, doors and glazed walls.
  • Page 2 When testing the detector settings you do not need to open it again as the tester will communicate with the detector acoustically. Never test the AD 700 with open lid. Make sure the lid is fastened properly. Caution: Do not use the ADT 700 tester in proximity to your ears as the tester produces loud noises.
  • Page 3 PROTECTING SEVERAL WINDOWS BY ONE DETECTOR Prepare the acoustic detector for DRC by following steps. The AD 700 can protect several windows in one room if the win- DIP switches inside the detector should be set as follows be- dows are within the coverage area. Make independent DRC fore testing.
  • Page 4 ABS plastic white, brown or black color Dimensions: 60x32x98 mm Security grade EN50131-2-7-1:2012, Grade 2, VdS Klasse B, SFS 1014-4 VdS G104512 Class B, SBSC Alarm Class 2 Approvals We reserve the right to changes without notice © 2016 Alarmtech 4 / 4 AD700 manual 1643en...