Servicing
A hazardous condition may result if a heater is used that has been modified or is not
functioning properly. When the heater is working properly:
* The flame is contained within the heater.
* The flame is essentially blue with perhaps some yellow tipping.
* There is no strong disagreeable odour, eye burning or other physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the heater.
The parts lists and exploded view show the heater as it was constructed. Do not
use a heater which is different from that shown. In this regard, use only the hose,
regulator and cylinder connection fitting (called a POL fitting) supplied with the
heater. IMPORTANT Match the color stripe on the hang tag attached to the hose
assembly with the color on the label located near the propane inlet fitting on the
heater. Do not use alternates. For this heater, the regulator comes factory set as
shown in "specifications". If there is any uncertainty about the regulator setting, have
it checked.
A heater which is not working right must be repaired, but only by a trained,
experienced service person.
In-warranty products will be repaired with no charge for either parts or labor. Please
include a brief statement indicating date, place of purchase, the nature of the
problem and proof of purchase.
Out-of-warrranty products will be repaired with a charge for parts and labor.
Storage
Make sure the heater is in off position.
Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
Disconnect the gas container from the gas heater.
Store the gas container in a cool, dry, dark and well-ventilated room. A
disconnected cylinder must have threaded valve plugs tightly installed. Position
it far away from inflammable, explosive or hot materials and preferably not in
the home. In addition it should never be stored in the basement or attic.
Cylinder must be stored out of the reach of children.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
When the heater is to be stored indoors, the connection between the LP-gas
supply cylinder(s) and the heater must be disconnected and the cylinder(s)
removed from the heater and stored out of doors.
Check the tightness of the gas valve and for damage. If you suspect a damage,
have it changed by your gas dealer.
Cleaning and Care
WARNING: Make sure the heater is in off position and is cool. Do not clean
heater with cleaners that are combustible or corrosive.
Wipe off powder coated surfaces with soft, moist rag and soap water.
Remove debris and spider and insect nests from ventilation opening of
the cylinder enclosure, control compartment, burner and circulation air
passageways of the heater with heavy duty pipe cleaner or compressed air to
keep appliance clean and safe for use.
Never clear ports or other openings with toothpicks or other article that will
break and block the ports.