READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, adjust or operate the heater.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarious, contactenos.
855-805-5745 • www.dewalt.com
VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS :
Lisez et observez toutes les instructions. Conservez ces
instructions dans un endroit sécuritaire pour vous y référer
ultérieurement. Interdisez à quiconque n'ayant pas lu les
présentes directives d'assembler, de régler ou de faire
fonctionner cette fournaise.
2018 - 40799 - CB
LEA CUIDADOSAMENTE LAS INSTRUCCIONES:
Lea y siga todas las instrucciones. Conserve
estas instrucciones en un lugar seguro para futura
referencia. No permita que nadie que no haya leído
estas instrucciones arme, ajuste o use el calentador.

Advertisement

Table of Contents
loading

Summary of Contents for DeWalt DXH50K

  • Page 1 MANUAL DE INSTRUCCIONES Kerosene Forced-Air Heater DXH50K, DXH75KT, DXH135KT, DXH185KT Kérosène air forcé Chauffage DXH50K, DXH75KT, DXH135KT, DXH185KT El queroseno calentador de aire forzado DXH50K, DXH75KT, DXH135KT, DXH185KT 2018 - 40799 - CB READ INSTRUCTIONS CAREFULLY: Read VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS : LEA CUIDADOSAMENTE LAS INSTRUCCIONES: and follow all instructions.
  • Page 2 • Do not operate in wet or damp conditions. WARNING: Fire, burn, inhalation, and explosion hazard. Keep solid combustibles, DXH50K & DXH75K WARNING: such as building materials, paper or cardboard, a safe distance away from Not suitable for use on wood floors or other combustible materials.
  • Page 3: Table Of Contents

    WARRANTY ..................12 INSTRUCTIONS FOR ORDERING PARTS ...........12 CAUTION: CSA certified for use with only No. 1-K kerosene fuel. Factory Tested: Specifications No.2-K kerosene, No.1 or No.2 Diesel, No.1 or No.2 fuel oil or JP8 Jet A fuel DXH50K DXH75KT DXH135KT DXH185KT...
  • Page 4: Warnings

    • dry mouth or sore throat 10. Operate only on a stable, level surface. (DXH50K & DXH75K—See wood floor warning). Be sure to follow advice about ventilation in the Safety Precautions section. 11. Do not use with duct work. Do not restrict inlet or exit.
  • Page 5: Maintenance, Storage And Service

    Locate heater at a safe distance from combustible materials. Models maintenance, cleaning and inspections. DXH50K & DXH75K are not suitable for use on wood floors or other combustible materials. When used, the heater should rest on suitable insulating material at least 1 inch thick and extending 3 ft. or more beyond...
  • Page 6 ADJUSTING PUMP PRESSURE Problem: Flame extends beyond the end of the heater. Due to varying fuel viscosities and normal component wear the pump pressure Adjustment: Pump pressure is too high. on this heater may need to be adjusted. The heater should only be operated at the manufacturer’s recommended burner setting.
  • Page 7: Wiring Diagram

    Annual Maintenance Schedule Wiring Diagram AIR OUTPUT FILTER. Remove the air output filter and tap the contaminated 18AWG GRN HI-LIMIT ON/OFF SWITCH SWITCH side gently on a solid object to remove contaminates. Compressed air or liquids 18AWG BLK 18AWG YELL should not be used to clean this filter.
  • Page 8: Trouble Shooting

    Diagnostic Safety Shutdown and Trouble Shooting See the following troubleshooting guide for unit status and corrective action if necessary. SYMPTOM TROUBLE SHOOTING High limit switch Open Circuit Make sure heater is cooled off, toggle switch to “OFF” position, wait 5 minutes and retry. Sparks, calling for flame, but Check wiring to motor (per wiring schematic in manual).
  • Page 9: Parts Lists/Exploded Views

    28749 28749 Large Retainer Washer 28750 28750 Cotter Pin 28751 28751 Hub Cap 21897 21897 Wheel Spacer 12** 21906 21907 Drape Guard 28787 28787 Hardware Kit DXH50K DXH75K 12** 21905 21905 Drape Guard Not Shown Required in Canada Figure 1.
  • Page 10 Parts List Ref. Item # Item # Item # Item# Description Ref. Item # Item # Item # Item # Description DXH50K DXH75K DXH135K DXH185K DXH50K DXH75K DXH135K DXH185K **** 40829 40829 40829 Thermostat Knob 40801 40801 **** **** Handle...
  • Page 12: Warranty

    Replacement parts are only available direct from the factory and must be installed by a qualified service agency. PARTS ORDERING INFORMATION: ® PURCHASING: Accessories may be purchased at any DeWalt local dealer or direct from the factory INSTRUCTION MANUAL...

This manual is also suitable for:

Dxh75ktDxh135ktDxh185kt