ABB MTQ22-FBP Manual

ABB MTQ22-FBP Manual

Softstarter type pse fieldbus plug modbus tcp

Advertisement

Quick Links

S O F TSTAR T ER T Y P E P S E
Fieldbus Communication
Fieldbus Plug Modbus TCP
PREPARED
2019-10-10
RELEASED
2019-12-18
OWNING ORGANIZATION
Drives softstarters
© Copyright 2019 ABB. All rights reserved.
STATUS
Approved
DOCUMENT KIND
Manual
DOCUMENT ID.
1SFC132374M0201
SECURITY LEVEL
Public
REV.
LANG.
PAGE
B
en
1/23

Advertisement

Table of Contents
loading

Summary of Contents for ABB MTQ22-FBP

  • Page 1 S O F TSTAR T ER T Y P E P S E Fieldbus Communication Fieldbus Plug Modbus TCP PREPARED STATUS SECURITY LEVEL 2019-10-10 Approved Public RELEASED DOCUMENT KIND 2019-12-18 Manual OWNING ORGANIZATION DOCUMENT ID. REV. LANG. PAGE Drives softstarters 1SFC132374M0201 1/23 © Copyright 2019 ABB. All rights reserved.
  • Page 2: Table Of Contents

    Diagnostics ..........................18 4.5.1. MTQ22-FBP ........................ 19 4.5.2. PSE Softstarter ......................19 5. MTQ22-FBP LED Diagnostics in Case of Error ............... 22 6. Basic TCP Modbus Diagnostic Information ................23 7. Contact us ..........................23 STATUS SECURITY LEVEL DOCUMENT ID.
  • Page 3 ABB Ltd and its affiliates are not liable for damages and/or losses related to such security breaches, any unauthorized access, interfer- ence, intrusion, leakage and/or theft of data or information.
  • Page 4: Overview

    IP datagrams removes the need for slave addresses since all slaves use a unique IP address to enable IP communication. However, The MTQ22-FBP still uses Modbus RTU to communicate with the PSE which require the slave ID to match between the MTQ22-FBP and the PSE, as ex- plained in section 3.2.
  • Page 5: Technical Description

    – The MTQ22-FBP Ethernet adapter module provides Ethernet connectivity for the ABB PSE softstarter Fieldbus plug (FBP) device. – Up to four FBP devices can be connected to one MTQ22-FBP. This allows a very cost-effi- cient connection of FBP devices to Ethernet.
  • Page 6: Mtq22-Fbp

    2.2. MTQ22-FBP A device layout of the MTQ22-FBP can be seen in Figure 1. Connectors X1 ... X4 are used to connect up to four FBP devices to the MTQ22-FBP. On the left side of the port connectors LEDs show the current communication status. See chapter 5 for detailed information regard- ing status LEDs.
  • Page 7: Connection Setup

    Fieldbus Plug Accessory (PS-FBPA) as seen in Figure 2. Further the PS-FBPA must be con- nected to one of the ports named X1 to X4 on the MTQ22-FBP. The Modbus master is in turn connected to one of the Ethernet connections E1 or E2.
  • Page 8: Software Configuration

    F I ELD BU S CO MMU N ICAT ION Software Configuration This chapter describes how to configure the MTQ22-FBP and the PSE to enable Modbus com- munication. 3.1. PSE Softstarter The following list of instructions explains how to configure the fieldbus parameters on the PSE softstarter.
  • Page 9 F I ELD BU S CO MMU N ICAT ION 3. Fieldbus Type The fieldbus type parameter must be set to FbP (fieldbus plug) when using the MTQ22-FBP. FbP is the default value of the parameter. The PSE has a built-in version of Modbus which is activated by setting the parameter to Int (Internal).
  • Page 10 Default value Setting range Description HAnd HAnd/Auto Hand require manual reset of fieldbus fault while Auto will perform the reset automati- cally. STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 10/23 © Copyright 2019 ABB. All rights reserved.
  • Page 11: Mtq22-Fbp

    (2) is used. On the PC the MTQ22-FBP configuration software must be installed (3). If the MTQ22-FBP is connected for the first time the required USB driver has to be installed. The Microsoft USB driver is not part of the software package because of license reasons. It is pre-installed on Windows 7 and 10, for XP it must be downloaded separately from Microsoft.
  • Page 12 1. After the application is started (as administrator) select the MTQ22-FBP that you want to configure in the Config Tool. 2. From the Select port drop down menu select the COM port associated to the MTQ22-FBP and click connect. The number of the COM port varies, make sure to select the one con- nected to the MTQ22-FBP.
  • Page 13 4. Select the connected FBP device and chose PSE in the drop-down menu called Expected device. For the ports without a connected device chose Port not used. STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 13/23 © Copyright 2019 ABB. All rights reserved.
  • Page 14 Device address read by the MTQ22-FBP. When the two Device addresses match for all connected PSEs click the Write to MTQ22-FBP button again. Note that, when the slave ID is updated in the PSE a reboot will be required on the PSE for the Config Tool to the detect the new value.
  • Page 15: Modbus Tcp Register Map

    Modbus TCP Register Map The following chapter shows how to generally access data of the FBP-devices connected to port one to port four of the MTQ22-FBP. Information Modbus TCP counts registers beginning with one. But on the bus registers start counting from zero.
  • Page 16 – The Auto mode input signal from the Modbus master (protocol address 0105h in the digi- tal output telegram) – The state of the Local/Remote switch on the Fieldbus Plug Accessory. STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 16/23 © Copyright 2019 ABB. All rights reserved.
  • Page 17: Digital Output Telegram

    Reserved 180Ch 181Ch 182Ch 183Ch Clear active Clear active diagnos- diagnostics tics when this coil is 180Dh 181Dh 182Dh 183Dh Reserved STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 17/23 © Copyright 2019 ABB. All rights reserved.
  • Page 18: Analog Input Telegram

    230Ah Run time in hours 4.4. Parameters The MTQ22-FBP does not support reading or writing PSE softstarter parameters such as start ramp time, initial voltage and torque control. 4.5. Diagnostics To read the diagnostics data, use Modbus function code 3 Read Holding Registers or 4 Read Input Registers.
  • Page 19: Mtq22-Fbp

    If a bit is set that fault is ac- tive and could potentially be resetted. STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 19/23 © Copyright 2019 ABB. All rights reserved.
  • Page 20 Parameter is read- This bit is set if a parame- only ter write operation failed due to the parameter be- ing read-only. STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 20/23 © Copyright 2019 ABB. All rights reserved.
  • Page 21 A “4” indicates the line cannot be determined or the problem exists on all three phases. STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 21/23 © Copyright 2019 ABB. All rights reserved.
  • Page 22: Mtq22-Fbp Led Diagnostics In Case Of Error

    F I ELD BU S CO MMU N ICAT ION MTQ22-FBP LED Diagnostics in Case of Error Diagnostic information is locally displayed using two Light Emitting Diodes (LEDs) per PSE device interface. The meaning of the LEDs is as follows.
  • Page 23: Basic Tcp Modbus Diagnostic Information

    – Motor will not start if there is an active fault (check the ready to start coil). Contact us For more information, please contact your local ABB representative or visit https://new.abb.com/drives/softstarters STATUS SECURITY LEVEL DOCUMENT ID. REV. LANG. PAGE Approved Public 1SFC132374M0201 23/23 © Copyright 2019 ABB. All rights reserved.

Table of Contents