Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear ear
instruction
protection
manual
1. SAFETY
WARNING! Damage to the human ear can begin at 85dB and above. Always wear ear defenders when testing the sound level in
a new situation. Do not assume that the sound level is safe until you have actually measured it.
WARNING! This equipment can be used in a wide variety of situations where noise is a concern including the home, traffic
situations, industrial environments, building sites, airports etc. In each case, the user of the equipment must familiarise themselves
with the safety regulations that apply to the particular situation in which the equipment will be used and do their own risk assessment in
order to stay safe and avoid personal injury.
Familiarise yourself with the applications, limitations, and potential hazards of the sound level meter.
9
Keep the sound level meter clean and in good condition.
9
Protect the sound level meter from electro-magnetic fields, static electricity and high temperatures.
9
Remain vigilant when using the sound level meter on, or near, machinery where there are rotational parts such as belts, pulleys and fans.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9
Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain and/ or tie back long hair.
9
DO NOT get the sound level meter wet or use in damp or wet locations or areas where there is condensation.
8
DO NOT use the sound level meter for any purpose other than for which it is designed.
8
DO NOT allow untrained persons to operate the sound level meter.
8
DO NOT operate the sound level meter when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
WARNING: The warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions
and situations that may occur. It must be understood that common sense and caution are factors which cannot be built into this
product, but must be applied by the operator.
2. INTRODUCTION
High quality meter suitable for measurement of environmental and
mechanical noise. Conforms to IEC61672-1 class 2 for sound meters.
Features min./max. measurements, over and under range,
A and C weighting, fast and slow response, data hold, record,
digital read-out and bar graph with backlight.
Supplied in storage case.
3. SPECIFICATION
Model no ......................................................................TA060
Accuracy .....................................................................±1.4dB
Frequency ........................................................... 31.5Hz-8Hz
Battery ..............................................................9v (supplied)
fig.1
© Jack Sealey Limited
SOUND LEVEL METER
TA060
MODEL NO:
SYMBOL
Original Language Version
MIN - Minimum sound level capture
MAX - Maximum sound level capture
FAST - sampling rate
DATA has been recorded
SLOW - sampling rate
Low battery indicator
Data hold function
C: Weighting, response to machine monitoring
A: Weighting, response to human hearing
Over upper limit of range
Under minimum limit of range
fig.2
FUNCTION
TA060 Issue:2 (H,F) 08/12/20

Advertisement

loading

Summary of Contents for Sealey TA060

  • Page 1 TA060 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 To Edit Year: Pressing the A/C button again you enter ‘edit year’ mode. Use the Level/Rec button to advance the number. Use the Max/Min button to decrease the number. Original Language Version TA060 Issue:2 (H,F) 08/12/20 © Jack Sealey Limited...
  • Page 3 When the battery symbol shows on the readout replace the 9V battery (PP9). BATTERY REMOVAL Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.