Troubleshooting - bora Classic 2.0 Operating Instructions Manual

Cooktop extractor and cooktops
Table of Contents

Advertisement

9

Troubleshooting

Observe all safety and warning information (see the Safety chapter).
X
X
Operating situation
System
The system won't switch on
(Power button
not visible)
The system switches itself off or
switches to standby mode
Power button
is flashing
Error code
C o n F
Error codes
,
d 15 ß p
E d 15 ß p
Colour differences between the
appliances
Cooktop extractor
Build-up of odours when new
cooktop extractor is in operation
The extraction performance of the
cooktop extractor has decreased
No extractor output,
red fan symbol
+
E F An
Reduced extractor output,
yellow fan symbol
+
F An
Error code
387
When setting a fan power level it jumps
straight back to 0,
fan symbol indicator
red
Error codes
,
E 0 8 1
E 0 ß p E n
Error codes
,
F 1L t
E F 1L t
www.bora.com
Cause
The fuse or automatic circuit breaker of the
electrical wiring system in the apartment and/or
house is defective
The fuse/automatic circuit breaker trips several
times
The power supply is disconnected
The micro fuse in the control unit's cooling
device plug connection is defective
The operating panel is dirty
Long press on power button (> 7 s)
Error signal during or after cleaning (power
button triggered by evaporating cleaning agents)
Object on the operating panel
The operating panel is dirty
Basic configuration incomplete
Object on the operating panel
The operating panel is dirty
Permanent activation of a touch zone
Extremely bright lights aimed directly at the
appliances
This is normal with brand new appliances
The grease filter is extremely dirty
The activated charcoal filter is extremely dirty
(only in recirculation mode)
There is an object in the air guiding housing (e.g.
cleaning cloth)
The fan is defective or a duct connection has
become loose
The fan has stopped working or is jammed
In a system with 2 fans, 1 fan has stopped working,
is jammed or is not connected correctly
Fan misconfiguration
No fan connected
The fan is jammed
There is no power supply to the fan
Home In not authorised
End of recirculation filter service life
Troubleshooting
= error  = information
E
Remedy
Replace the fuse
Switch the automatic circuit breaker back on
Contact the BORA Service Team
Have a specialist electrician inspect the power
supply
Replace the fuse (type: T 3.15A/250V)
Clean the operating panel
Dry the power button immediately after
cleaning (< 7 s)
Use the cleaning lock Clean using a dry cloth
Remove the object from the operating panel
Clean the operating panel
Complete basic configuration
Remove the object from the operating panel
Clean the operating panel
Cancel permanent activation
Avoid using spotlights and ensure that lighting
is even
Odours stop forming after a few operating
hours
Clean or replace the grease filter
Replace the activated charcoal filter
Remove the object
Contact the BORA Service Team
Contact the BORA Service Team (the system
can be used but without the extraction
function)
Contact the BORA Service Team (the system
can be used but with reduced extraction
function)
Starting fan configuration
Connect the fan
Contact the BORA Service Team
Check the fan connection
Open window and then tap the fan button
Fit a new filter (only in the case of
recirculation) and reset the filter service life
(see Menu item B).