ABB EP010 User's And Operator's Manual page 23

Modbus / fbp interface
Table of Contents

Advertisement

# Name/Description
43 Loc Bus Relais 3 Delay
44 Loc Bus Relais 4 Function
45 Loc Bus Relais 4 Delay
46 Loc Bus Relais 6 Function
47 Loc Bus Relais 6 Delay
48 Loc Bus Relais 7 Function
49 Loc Bus Relais 7 Delay
50 Loc Bus Relais 8 Function
51 Loc Bus Relais 8 Delay
52 P relais Contact config
0: Relay P1
1: Relay P2
2: Relay P3
3: Relay P4
4: Contact P1
5: Contact P2
6: Contact P3
7: Contact P4
8-15: not used
53 P1 Function
54 P1 Delay
55 P2 Function
56 P2 Delay
57 P3 Function
58 P3 Delay
59 P4 Function
60 P4 Delay
61 Programmable Input config
62 Programmable Input Function
63 Programmable Input Delay
64 Data Logger Config
65 Data Logger Trigger Type
66 Data Logger Stop Delay
67 Data Logger Frequency
ϕ
68 Cos
Module Threshold
69
CB TAG name 1
70
CB TAG name 2
71
User data 1
72
User data 2
73 Dual set CB close time
74 Date of installation CB
75 Date of last maint CB
76 Port L configuration
0-3: not used
4: Thermal mem
5-15: not used
77 Prot L curve type
78
Prot L threshold
79
Prot L time
80
Prot L threshold IEC255
81
Prot L time IEC255
82
Prot S configuration
0: Prot enable/disable
1: not used
2: Start Up Th
3: Zone sel
4: Thermal mem
ABB SACE
Range
Units Multipler Coding
{0.00 ... 100.00}, step 0.01
s
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm | LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm | LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm | LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm | LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
Not Latched | Latched
Not Latched | Latched
Not Latched | Latched
Not Latched | Latched
NO | NC
NO | NC
NO | NC
NO | NC
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm|LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm| LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm|LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
None | L prealarm | L timing |
S Timing | L trip | S trip | I trip |
G trip| Any trip| Any Alarm| LC1|
LC2 | Custom
{0.00 ... 100.00}, step 0.01
s
Active High | Active Low
Generic|External TRIP|Trip reset|
Set B (PR123 only) | Dial Local |
Reset Signalling Module|
Energy reset
{0.00 ... 100.00}, step 0.01
s
OFF | ON
None (free running)|Any Alarm|
L Timing | Any Trip | Custom
{0.00 ... 100.00}, step 0.01
s
600 | 1200 | 2400 | 4800
Hz
{0.50 ... 0.95}, step 0.01
{0.20 ... 50.00}, step 0.10
s
Number of days from 31/12/1999
Number of days from 31/12/1999
OFF | ON
I2t=k1|0,14/(i0.02-1)|13,5*b/(i-1)|
80*b/(i2-1)
{0.40 ... 1.00}, step 0.01
In
{3 ... 144}, step 3
s
{0.40 ... 1.00}, step 0.01
In
{3 ... 144}, step 3
s
Enable | Disable
OFF | ON
OFF | ON
OFF | ON
EP010
Lenght
Range
[bytes]
default
100
2
{0 ... 65535}
2
100
2
{0 ... 65535}
2
100
2
{0 ... 65535}
2
100
2
{0 ... 65535}
2
100
2
2
0 | 1
0 | 1
0 | 1
0 | 1
0 | 1
0 | 1
0 | 1
0 | 1
{0 ... 65535}
2
100
2
{0 ... 65535}
2
100
2
{0 ... 65535}
2
100
2
{0 ... 65535}
2
100
2
0 | 1
2
0 | 1 | 2 | 3 |
2
4 | 5 | 6
100
2
0 | 1
2
0 | 1 | 2 | 3 |
{256 ... 65535}
2
100
2
0 | 1 | 2 | 3
2
100
2
1 byte for char.
6
(ASCII)
1 byte for char.
4
(ASCII)
1 byte for char.
6
(ASCII)
1 byte for char.
4
(ASCII)
100
2
2
2
2
0 | 1
0 | 1 | 2 | 3
2
100
2
100
2
100
2
100
2
2
0 | 1
0 | 1
0 | 1
0 | 1
1SDH000510R0001
Notes
Read only PR123 only
0
None
0
None
0
None
0
None
0
None
0
None
0
None
0
None
0
Active High
Generic
0
OFF
None
0
600
0.5
Yes
0.20
Yes
I2t = k1
0.4
3
0.4
3
Page N.
L2388
22/28