9.1.3

Central heating menu

The central heating menu has 3 settings and is accessible by
gently tapping on the Central Heating symbol
main menu.
Within the central heating menu:
► the maximum temperature of the central heating water can
be adjusted
► access to the RF menu
► the timer function can be adjusted
The following symbols will illuminate:
► The Minus symbol
► The Plus symbol
► The Enter symbol
The Domestic Hot Water symbol
The left section will illuminate and the current preset
temperature of the central heating water will be displayed.
To adjust the central heating water temperature setting:
1. Tap the Central Heating symbol
is displayed on the left side of the fascia.
2. Using the Plus
temperature (for example, 60°C).
3. Tap the Enter button
P P
A
appears on the right display (all other buttons are
extinguished), which means the setting has been stored.
4. The display returns to the main menu.
9.1.4

RF menu

The Xclusive range of boilers have a built-in Ramses 2 RF
transmitting/receiving module, this allows the boiler to
wirelessly communicate with Honeywell OpenTherm room
thermostats T87RF2025 Round, CMS927 & CMS727.
Assignment of the thermostat and additional settings can be
made via the RF menu.
The RF menu is accessible by touching and holding the Central
Heating symbol
can then be made:
► Assign RF thermostat
► Remove assignment between boiler and RF thermostat
The following symbols will illuminate:
► The Service symbol
► The Enter symbol
The left display will illuminate and, depending on the
assignment of the boiler, will show 'rF1–' or 'rF1'.
rF1–:
Boiler and thermostat are not assigned.
rF1:
Boiler and thermostat are assigned.
Tap the Enter symbol
to the main menu.
To exit the RF menu without saving your settings tap the fascia
display just above the power LED, this will take you back to the
original menu or standby mode.
54
will be extinguished.
. The target temperature
and Minus
symbols, set the desired
to confirm (or wait 30 seconds).
for 2 seconds. The following adjustments
(or wait 1 minute) to save and return
from the
Main menu
Central heating
menu
Confirm
Central heating
menu
RF menu (not assigned)
RF menu (assigned)
Smart Opentherm™
2sec

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xclusive 24 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF