Specifications
Generator
Displacement
Compression Ratio
Engine Type
Cooling System
Fuel
Engine Oil
Run Time @ 25% Load
with full tank
Sound Level at 23 feet, 25% load
Bore x Stroke
Spark Plug
Valve Clearance
Engine Speed
The emissions control system for this Engine is warranted for standards set by the
U.S. Environmental Protection Agency and by the California Air Resources Board (also known as CARB).
For warranty information, refer to the last pages of this manual.
Page 2
Table of Contents
Output
Receptacles
Type
Capacity
Type SAE
Capacity
Type
Gap
Intake
Exhaust
For technical questions, please call 1-888-866-5797.
Maintenance ................................................................ 15
Troubleshooting ........................................................... 19
Warranties ................................................................... 26
120/240 V AC, 60 H z, 63.3 / 31.7 A , 1 Phase
12 V DC, 8 A (nominal)
5V USB, 3.1A
7600 Running Watts
9500 Maximum Starting Watts
2 x GFCI NEMA #5-20R (3-prong, 120 V AC)
1 x NEMA #L5-30R (3-prong, 120 V AC)
1x NEMA #L14-30R (4-prong, 120/240 VAC)
1 x 12 V DC Two Pin Outlet
2 x USB-A Outlets
Parallel Kit Terminals
459 c c
8.5:1
Horizontal Single Cylinder
4-stroke, OHV
Forced air cooled
87+ octane, stabilizer-treated
unleaded gasoline
6.8 Gallons
10W-30
37 fl. oz.
18.5 hr.
67 dB
92mm x 69mm
BPR6ES (NGK) or equivalent
0.027"– 0 .031"
0.0039"– 0 .0059"
0.0059"– 0 .0078"
2560 - 3410 RPM
ITEM 57080
Need help?
Do you have a question about the Predator 9500 and is the answer not in the manual?
Questions and answers
When shutting off the generator (non-emergency) do you also turn off the Engine On/Off switch. The directions never mention to turn off this switch except if it is an emergency. It seems obvious that you would instead of only shutting off the Combination switch to starve it of gas.... help!
Yes, under normal conditions, the generator should be shut down by turning off all electrical load devices, unplugging them, turning the Economy (ESC) Switch off if it was on, and then turning the Combination Switch off. The Engine On/Off switch is not mentioned as part of the normal shutdown procedure but should be turned off in an emergency.
This answer is automatically generated
I need to buy the monoxide sensor for a Predator 9500. Where can I buy it, I'm from Puerto Rico.