4-2-8. Video Input Check

1. Refer to Section 4-1-2, and start the Diag mode.
2. Refer to steps (1) and (2), and input the color-bar
signal to the VIDEO IN AUX IN connector of the unit.
(1) Connect the unit's VIDEO IN AUX IN and
VIDEO OUT AUX connectors using the video
cable with a connector (supplied accessary).
(2) Enter the following command from the terminal
PC, and check the response status.
command> cb cenc ↓
Color Bars on VOA( 1, 2 ) CENC screen
3. Enter the following command from the terminal PC,
and check the response status.
command> videoin 0 2 ↓
command> vlpc y 135 330 ↓
0xXX
4. Check that the response status "0xXX" is within
specification.
Specification: 0x98 to 0xb6
5. Enter the following command from the terminal PC,
and check the response status.
command> vlpc b 405 330 ↓
0xXX
6. Check that the response status "0xXX" is within
specification.
Specification: 0xa9 to 0xbd
7. Enter the following command from the terminal PC,
and check the response status.
command> vlpc r 405 330 ↓
0xXX
8. Check that the response status "0xXX" is within
specification.
Specification: 0xb7 to 0xcf
9. After checking, enter the following command from the
terminal PC.
command> videovfp 4 0 ↓
command> cb off ↓
command> videoin 0 0 ↓
command> videoin 1 0 ↓
4-28
4-3. Operation Check in Application
Mode (Normal Operation)
In this Section, the command (written in bold) input from
the terminal PC and the response status are described as
follows.
(Example)
pcsdb> cntr ↓: Enter "cntr" from the terminal PC,
and press the Enter key.
Response status for entering "cntr".
ok:

4-3-1. Network Interface Check

Check if the network interface is normal. Perform the
check by connecting the network cable from a device, such
as a HUB, to the 100BASE-TX/10BASE-T connector of
the unit.

4-3-2. Initial Setting Check

1. Refer to Section 4-1-1, and start the terminal software.
2. Enter the following command from the terminal PC,
and check the response status.
pcsdb> cntr ↓
ok
3. Enter the following command from the terminal PC,
and check the initial setting of the unit.
status machine ↓
PCS-G50
xxxxxxxxxx
Ver.xx.xx
Ver.xx.xx
xxx.xxx.xxx.xxx
xx-xx-xx-xx-xx-xx: MAC address
optionline-xx
optionrgb-xx
optionh320mcu-xx : 320MCU Option (with/without)
optionh323mcu-xx : 323MCU Option (with/without)
optionwb-xx
4. After checking, enter the following command and end
the terminal software.
exit ↓
ok
: Serial number
: HOST version
: DSP version
: IP address
: Option Line (with/without)
: DSB (with/without)
: White board Option (with/without)