Sole Diesel SCO 5 Operator's Manual

Sole Diesel SCO 5 Operator's Manual

Generator control panel
Hide thumbs Also See for SCO 5:

Advertisement

Generator Control
Panel
Operator's Manual
SCO 5
SCO 10
U_FA1150_EN
Revision 0
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com
Manual del operador. Panel de control del Generador.
Solé Diesel, S.A. C-24
Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCO 5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sole Diesel SCO 5

  • Page 1 Solé Diesel, S.A. C-24 Manual Generator Control Panel Operator’s Manual SCO 5 SCO 10 U_FA1150_EN Revision 0 Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Manual del operador. Panel de control del Generador.
  • Page 3: Table Of Contents

    Section 6 – Sensors and switches specifications ................29 Section 7 – Optional equipment......................31 7.1. Panel SCO 5 / Panel SCO 10 amperometric pack ..............31 7.2. SCO 10 second panel kit ......................31 Section 8 – Electrical wiring diagrams ....................32 8.1.
  • Page 4: Section 1 - Introduction To The Sco

    Introduction to the SCO Section 1 – Introduction to the SCO The SCO it is a control and protection panel used for generating sets; it shows the settings measured on its displays. The Unit is designed for easy use, for both installer and end-user alike. Remote control The SCO controller can be remotely controlled.
  • Page 5: Section 2 - Technical Data

    Technical data Section 2 – Technical data Technical Data Power supply SCO 5 SCO 10 Voltage supply 8 V to 36 V DC 8 V to 36 V DC 60 mA to 12V DC 80 mA to 12V DC Consumption...
  • Page 6: Section 3 - Installation

    Installation Section 3 – Installation 3.1. SCO 5 panel installation The controller is to be mounted onto the switchboard door. Requested cutout size is 96 mm x 96mm. Use the screw holders delivered with the controller to fix the controller into the door as described on the pictures below.
  • Page 7: Section 4 - Sco 5 Panel Operation

    SCO 5 panel operation Section 4 – SCO 5 panel operation 4.1. Buttons and indicators POSITION BUTTON DESCRIPTION Graphic B/W display. 128 x 64 pixels. Alarm red LED. The LED will blink when there is one or more active warning or active shutdown alarm.
  • Page 8: Display Screens And Pages Structure

    SCO 5 panel operation 4.2. Display screens and pages structure The displayed information is structured into "pages" and "screens". Use buttons ▲ or ▼ to change the screen page. Voltage (V) Power (kW) Frequency (Hz) Operation hours Engine speed (RPM)
  • Page 9: Alarms, Events And History

    SCO 5 panel operation Oil pressure (Bar) Coolant temperature (ºC) Fuel level* (%) Battery voltage (V) Total power (kWh) Total R power (kVarh) Alarms, events and history Return to the main screen 4.3. Alarms, Events and History The folowing list shows the type of events and alarms that may appear in the history.
  • Page 10: Events List

    SCO 5 panel operation A symbol corresponding to an event appears on the display followed by a number that indicates the total number of hours of the engine in which the event occurred. 4.3.1. Events list SYMBOL DESCRIPTION Manual start: Engine was manually started by pressing button START in Manual mode.
  • Page 11: Warnings List

    SCO 5 panel operation 4.3.2. Warnings list Active warning: When a warning occurs, O04 Alarm and O15 Common Warning outputs will close and the red LED above STOP button will blink. Warning symbol will blink in the upper-right corner of the LCD and the proper warning symbol will be displayed in the history with running hours stamp.
  • Page 12 SCO 5 panel operation Binary inputs (Negative signal “-”): Low oil pressure (I13) Remote Start/Stop or Exhaust temperature (I12) * High coolant temperature (I08) Emergency stop (I04) Binary outputs (Positive signal “+”): Buzzer (O10) Preheating (O05) Fuel feed pump (O07)
  • Page 13 SCO 5 panel operation SYMBOL DESCRIPTION Emergency stop: the binary input (IO4) is activated. Overspeed: The protection comes active if the speed is greater than 120 % of nominal engine RPM. Actual speed value is derived from genset frequency or is sensed directly using magnetic pick-up input.
  • Page 14 SCO 5 panel operation SYMBOL DESCRIPTION Generator Overfrequency: The genset frequency is out of limits given by setpoints G03 Generator Overfrequency Shutdown and G04 Generator Underfrequency Shutdown. Generator Underfrequency: The genset frequency is out of limits given by setpoints G03 Generator Overfrequency Shutdown and G04 Generator Underfrequency Shutdown.
  • Page 15: Connections Description

    SCO 5 panel operation 4.4. Connections description Code Terminal Signal type Description Color Analog input Oil pressure sensor Brown Analog input Coolant temperature sensor Grey Binary input Oil pressure switch Blue Binary input Exhaust temperature switch Purple Black Binary output...
  • Page 16: Section 5 - Sco 10 Panel Operation

    SCO 10 panel operation Section 5 – SCO 10 panel operation 5.1. Buttons and indicators GENSET CONTROL BUTTONS POSITION BUTTON DESCRIPTION START button. Works in MAN mode only. Press this button to initiate the start sequence of the engine. STOP button. Works in MAN mode only. Press this button to initiate the stop sequence of the genset.
  • Page 17 SCO 10 panel operation POSITION BUTTON DESCRIPTION MODE LEFT button. Use this button to change the mode. The button works only if the main screen with the indicator of currently selected mode is displayed. Note: This button will not work if the controller mode is forced by one of the binary inputs Remote OFF, Remote MAN, Remote AUT.
  • Page 18: Display Screens And Pages Structure

    SCO 10 panel operation 5.2. Display screens and pages structure The displayed information is structured into "pages" and "screens". Use PAGE button to switch over the pages. 1. The Measurement page consists of screens which display measured values like voltages, current, oil pressure etc., computed values like genset power, statistic data and the alarm list on the last screen.
  • Page 19 SCO 10 panel operation Binary Inputs – Binary signals from the genset to control panel. BI1: Remote control – Start or Stop • • BI2: Alarm / Temperature switch (shutdown) • BI3: Emergency STOP. • BI4: Alarm / Pressure switch •...
  • Page 20: Setpoint. Controller Information Screen

    SCO 10 panel operation 5.2.2. Setpoint. Controller information screen Enter Page Hold the ENTER and PAGE button at the Page same time. Page Page Enter If the panel is more than 5 seconds in a screen, it returns to initial screen automatically. In this case, you must begin all the procedure again.
  • Page 21: Setpoint. Maintenance Hours Change

    SCO 10 panel operation 5.2.3. Setpoint. Maintenance hours change When the following warning appears in the Alarm list screen of SCO 10: First of all you must carry out the maintenance tasks according to the Maintenance task table, attached in the end. You also can consult this information in the Warranty manual.
  • Page 22: History Log

    SCO 10 panel operation 5.2.4. History Log Page Page Enter To display all the screens shown below, you must press "ENTER”. Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Operator’s manual.
  • Page 23: Alarms List

    SCO 10 panel operation 5.2.5. Alarms list Fault Reset Active unconfirmed alarm Active confirmed alarm Alarm desactivation 5.2.6. Display contrast adjustment Enter Enter Hold ENTER button and, ↑ or ↓at the same time. Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Operator’s manual.
  • Page 24: Change Language

    SCO 10 panel operation 5.2.7. Change language If the panel is more than 5 seconds in a screen, it returns You must follow these steps to change the panel language. to initial screen automatically. In this case, you must begin all the procedure again.
  • Page 25: Alarm Management

    SCO 10 panel operation 5.3. Alarm management The following alarms are available: • Breaker open and cooling (BOC) • Warning • Shut down 5.3.1. Breaker open and cooling (BOC) When the control panel detects a problem related to the alternator. The panel stops the genset gradually.
  • Page 26: Genset Operation States

    SCO 10 panel operation 5.4. Genset operation states 5.4.1. Engine status list Init Autotest during controller power on Not ready Genset is not ready to start Prestart Prestart sequence in process, Prestart output is closed Cranking Engine is cranking Pause Pause between start attempts Starting Starting speed is reached and the Idle timer is running...
  • Page 27 SCO 10 panel operation Configurable Warning/BOC/Shutdown alarms on the inputs of IL-NT. IOM Bin Inp CONFIG. Configurable Warning/BOC/Shutdown alarms on the IL-NT-BIO8 CONFIG inputs of IG-IOM/IGS-PTM. ActCallCH1Fail Active call on channel 1 failed. ActCallCH2Fail Active call on channel 2 failed. RTC backup battery is flat BackupBatt ChargeAlt Fail...
  • Page 28 SCO 10 panel operation Warning alarm in case of lost connection to IGL-RA15 Wrn RA15 Fail module. Wrong checksum of parameters. Happens typically after downloading new firmware or changing of the ParamFail parameter. The controller stays in INIT mode. Check all parameters, write at least one new parameter.
  • Page 29: Section 6 - Sensors And Switches Specifications

    Sensors and switches specifications Section 6 – Sensors and switches specifications Coolant temperature sensor: Function table Temperature Resistance Tolerance Operating voltage: 6-24V (ºC) (ohm) (ohm) Operating current: <85mA, Pmax<0.25W 287.4 ±32.8 Operating temperature: -40°C to +120°C Measuring range: -40°C to +120°C ±13.5 Absolute max.
  • Page 30 Sensors and switches specifications Oil pressure sensor (two pole): Function table Pressure Resistance Tolerance Operating voltage: 6-24V (BAR) (ohm) (ohm) Operating current: >20mA, <85mA, Pmax<0.25W +3/-5 Operating temperature: -20°C to +100°C Measuring range: 0 – 10 BAR ±4 Absolute max. value: 30 BAR, max. 2 seconds. ±4 Protection: BODY IP 67 ±5...
  • Page 31: Section 7 - Optional Equipment

    Optional equipment Section 7 – Optional equipment 7.1. Panel SCO 5 / Panel SCO 10 amperometric pack In order to measure the phase current, it is necessary to install the amperometric pack, supplied as an option. The necessary toroidal transformers are included in each pack and must be suitable for each genset set model.
  • Page 32: Section 8 - Electrical Wiring Diagrams

    Electrical wiring diagrams electrica Section 8 – Electrical wiring diagrams 8.1. SCO 5 panel: Monophasic gensets Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Operator’s manual. Generator Control Panel...
  • Page 33: Sco 5 Panel: Triphasic Gensets

    Electrical wiring diagrams electrica 8.2. SCO 5 panel: Triphasic gensets Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Operator’s manual. Generator Control Panel...
  • Page 34: Sco 10 Panel: Monophasic Gensets

    Electrical wiring diagrams electrica 8.3. SCO 10 panel: Monophasic gensets Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Operator’s manual. Generator Control Panel...
  • Page 35: Sco 10 Panel: Triphasic Gensets

    Electrical wiring diagrams electrica 8.4. SCO 10 panel: Triphasic gensets Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · info@solediesel.com Operator’s manual. Generator Control Panel...
  • Page 38 U_FA1150_EN Revision 0 04/2020...