Future Automation TTR60 Instruction Sheet

Su / cme swivel unit

Advertisement

SU / CME
Instruction Sheet
Your Pack Should Contain
WARNING
It is the responsiblity of
the installer to warn all
potential end users of
the dangers of interfering
with mechanisms during
operation
Swivel Unit
www.futureautomation.co.uk
IMPORTANT
Mechanisms which lift
or move weights need
to be checked on a
yearly basis for any
damage which may
result in an accident
Sheet 1 of 7
ISSUE: 004
1
Control
Box
FUTURE AUTOMATION
FUNCTION
A remote controlled
universal swivel unit.
To be used as a ceiling
mounted or under table
mounted swivel unit.
Allows for up to 180
of movement clockwise
and counter-clockwise.
See specific technical
sheets for mounting
guidelines.
1
Remote
Control

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTR60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Future Automation TTR60

  • Page 1 It is the responsiblity of Mechanisms which lift the installer to warn all or move weights need potential end users of to be checked on a FUTURE AUTOMATION the dangers of interfering yearly basis for any with mechanisms during damage which may operation...
  • Page 2: Remote Controls

    # 14 Rotates screen right # 8 + # 11 within 1sec Sets limits to 180 # 8 + # 10 within 1 sec Sets left limit # 8 + # 12 within 1 sec Sets right limit PRESS PRESS HOME FUTURE AUTOMATION...
  • Page 3: Position Options

    # 13 or # 14 anti-clockwise. To start the Then press #3 to stop, screen rotating followed by pressing clockwise or #5 to store. anti-clockwise PRESS To stop the screen in the desired position PRESS To store the FUTURE AUTOMATION position in the memory...
  • Page 4: Electrical Connections

    It is VERY important that when all of the electrical connections are made, the connector blocks are connected in the way shown above, with all the wires coming directly out the top of the connector blocks. Connect the IEC Power Lead Here FUTURE AUTOMATION...
  • Page 5: Contact Closure

    When short removed, device will go IN. When shorted to ground, DEVICE STOP stops device in current position. Momentary short to ground W/BR W/BR DEVICE OUT will make device go OUT. Momentary short to ground DEVICE IN will make device go IN. FUTURE AUTOMATION...
  • Page 6 = Device FORWARD fa right, = Device to RIGHT limit pins fa left, = Device to LEFT limit PIN 1: IN PIN 2: IN PIN 6: OUT PIN 3: OUT PIN 3&4: GROUND PIN 5: GROUND FUTURE AUTOMATION...
  • Page 7: Operation Details

    / removed. Red LED will also be on. Gives an ouput of 240V(or 110V) to control the Swivel Unit motor. Outputs stay live for 60 seconds after FUTURE AUTOMATION the OUT or IN fuctions are selected.