Intelligent duct smoke detectors

Advertisement

Quick Links

Innovair
Intelligent
Duct Smoke Detectors
Intelligent Models Available
DH200P (non-relay)
DH200RP (with relay)
Product Overview
Air velocity rating from 500 to 4000
feet per minute (2.54 to 20.32 m/sec.)
Patented telescopic sampling tube
Easily accessible code wheels
Outside mounting tabs
Easy and quick mounting to round
or rectangular ducts from 1'–12'
(0.3–3.7 meters) wide
Easy to clean
UL recognized field-replaceable
power and sensor boards
Transparent cover for convenient
visual inspection
UL 268A listed
3-year warranty
DH200P (non-relay)
Has outputs for remote LED display,
remote test
Incorporates zener diodes to conserve
power for communications to other
devices
Com line power only
DH200RP (with relay)
Powered outputs for remote LED, remote
test and sounder
Two form "C" auxiliary contacts
Can be configured as a relay version or
jumpered to mimic a non-relay version
Patented cover tamper trouble signal
Requires both com line power and one of
the following: 24VAC/DC or
120/220VAC for operation
®
200 Series
DH200P
The System Sensor Innovair
capable of sensing smoke in air velocities from 500 to 4,000 feet per minute (2.54 to
20.32 m/sec).
The DH200 Series Detector samples air currents passing through a duct and gives
dependable performance for shutdown of fans, blowers, and air conditioning systems,
preventing the spread of toxic smoke and fire gases through the protected area.
These intelligent sensors communicate and are continuously monitored through the com-
munication line. Detector sensitivity changes caused by dirt, temperature, or humidity
are reported to the panel, allowing compensation algorithms to maintain the sensor's set
sensitivity. An advance indication at the panel specifies the sensor address, allowing for
selected maintenance to be performed as needed.
Remote alarm annunciation can be accomplished by using the RA400Z Remote
Annunciator or the RTS451 or RTS451KEY Remote Test Station. Both these devices
allow testing of the detector from a remote location.
The Innovair family is designed for simplified installation and easy maintenance. The
modular construction allows for easy cleaning and uncomplicated field replacement of the
UL recognized power and sensor board
Duct smoke detectors have specific limitations.
WARNING:
DUCT SMOKE DETECTORS ARE:
NOT a substitute for an open area smoke detector,
NOT a substitute for early warning detection, and
NOT a replacement for a building's regular fire detection system.
Refer to NFPA 72 and 90A for additional duct smoke detector application information.
DH200RP
DH200 Series photoelectric air duct smoke detectors are
s.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Innovair 200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for System Sensor Innovair 200 Series

  • Page 1 (2.54 to 20.32 m/sec.) Patented telescopic sampling tube Easily accessible code wheels Outside mounting tabs Easy and quick mounting to round The System Sensor Innovair ™ DH200 Series photoelectric air duct smoke detectors are or rectangular ducts from 1′–12′ (0.3–3.7 meters) wide capable of sensing smoke in air velocities from 500 to 4,000 feet per minute (2.54 to...
  • Page 2 Architect/Engineer Specifications The duct smoke detector shall be a System shall be an intelligent photoelectronic shall be included to reduce dust and Sensor Model DH200P or DH200RP detector. It shall be capable of local testing residue effects, thereby reducing mainte- Intelligent Series Duct Smoke Detector to via magnetic switch or remote testing from nance and servicing.
  • Page 3 DH200RP Specifications Current Requirements (using no accessories) Power supply voltage 20-30 VDC 24 VAC, 50-60HZ 120VAC, 50-60Hz 220/240 VAC, 50-60Hz Max. standby current 26 mA 65 mA RMS 44 mA RMS 25 mA RMS Max. alarm current 87 mA 182 mA RMS 52 mA RMS 30 mA RMS Alarm response time...
  • Page 4 System Sensor in Singapore System Sensor – Australia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.273.2230 Ph: 613.54.281.142 Documents-on-Demand Fx: 44.1403.276501 Fx: 65.273.2610 Fx: 613.54.281.172 800/736-7672 x3 www.systemsensor.com © 2000 System Sensor. The company reserves the right to change product specifications without notice. A05-0280-001•12/00(5K)•#712...

This manual is also suitable for:

Innovair dh200pInnovair dh200rp