Page 1
User Manual This document discloses data in which Opgal Inc. has proprietary rights. Neither the furnishing, receipt, nor possession thereof confers upon or transfers any right to reproduce or disclose the document, any part thereof, or any information therein except by written permission from, or written agreement with, Opgal Inc.
α- Si bolometer 17µ 384x288 pixels. 2 Disclaimer Therm-App MD does not detect fevers or illness in any way. It is not a medical diagnostic tool and has not been approved by a medical professional. Any individual tested and flagged should be double- checked using an approved medical device.
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 4 Application Operation 4.1 Initialization When first connecting Therm-App® to the Android device, proceed as follows: Select Use by default for this USB device checkbox and tap OK. The Therm-App® application will automatically start and display the Terms and conditions screen.
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 4.2 Selecting Night Vision / Thermography Color Palettes On each imaging mode, the Therm-App® device image can be displayed using one of several palettes. To change the selected palette, swipe your finger or select by the mouse across the image on the...
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 4.5 Image Display Full Screen Mode ◼ By tapping the screen twice quickly, you can switch between standard and full screen modes. The screen mode allows landscape configuration for use of HDMI screens. Digital Zoom & Pan ◼...
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 4.6 Lower Toolbar Gallery [1] – Displays pictures stored on the ◼ Android device using the default album application. – ◼ Snapshot [2] Takes a snapshot of the image displayed on the screen. – Records a video stream of ◼...
5.1 Preparation For best performance, the ambient room temperature should be 25°c (77°F). For optimal performance wait 40 minutes or more from start-up to allow the Therm-App to reach an initial steady temperature state. In order to establish a baseline temperature, have three healthy people with regular temperatures pass in front of the camera.
Configure Temperature Alerts [5] After you have turned on temperature alerts [3], you can set the Therm-App® to flash a red alert when it finds something below a certain temperature (snowflake icon) or above a certain temperature (flame icon). The box flashes red once a subject inside it crosses the preset temperature.
(See page 12 for full walkthrough). ◼ Maintenance – Performs bad pixel repair and resets all parameters to default. ◼ Help – Link to User Manual, Therm-App® Support, and Terms of Use. About – General application and device version ◼ information.
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 5.4 Main Menu Options Imaging Mode Night Vision – This mode maximizes the difference ◼ between hot objects and their surrounding and is used for night-time detection of various targets. Imaging Mode – switches between "Night Vision" and "Thermography"...
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 5.5 Thermography Settings ◼ Units – select between Celsius and Fahrenheit. Emissivity – Emissivity is the ability of the surface of a ◼ material to emit energy as thermal radiation. The emissivity value (0 – 1) represents the ratio of energy radiated by the observed material to the energy radiated by a black body at the same temperature.
Therm-App® (only valid when Therm-App® is connected and image is shown). ◼ Gain Limit Mode - Therm-App® is using noise filter by averaging frames for temporal noise reduction. ◼ Alert Mode Settings – Allows you to configure Alert Mode settings.
Page 15
(SBC, Tablet, Smartphone) connected to The Internet. Multiple devices can view the stream from a single Therm-App®. A solid Internet connection is required to obtain good video quality. To activate streaming: ◼...
Page 16
Language – Select your preferred interface language (Match Phone, English, Chinese, Thai, German, French, Russian, or Spanish). Match phone is the default. If this feature is selected, the Therm-App® application will detect the language on your phone and attempt to match it. ------------------------------------------------------------------------------------------------------------------------------------------------------------...
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 5.7 Export/Save Options Following extensive operation of the thermal ◼ sensor, or due to mechanical shock, some pixels may need digital repair. Bad pixels are observed as pixels that are darker or brighter than their surroundings.
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 6 Help In the Help heading you will find options for: Manual ◼ Therm-App® support ◼ Terms of use ◼ 7 About In the About section you will find information about the device, including serial number, application version, firmware version, and hardware version.
9) I’m not getting a temperature reading and the screen says “overflow”. This occurs if an object in the screen surpasses 60°c (140°F), which is beyond our calibration range. Remove the object and check again. If this error still occurs, reinstall the Therm-App app from an APK provided to you by your account manager.
LICENSE GRANT. You have purchased a Product that includes Therm-App MD branded software modules owned or licensed by Opgal. With respect to Therm-App MD mobile Apps owned or licensed by Opgal, Opgal grants you a non-exclusive license to use the Therm- App MD branded software modules and the Therm-App MD branded mobile Apps (subject to the payment and usage terms applicable to each Therm-App MD branded App), as well as associated media, user instructions, manuals, printed materials, and “online”...
Page 21
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Mobile Device Compatibility Requirements. Currently the Product may only be used with a Compatible Mobile Device running Android operating system version 5.1 and above supporting USB Host mode (USB-OTG "USB On The Go"). NO WARRANTIES FOR THE SOFTWARE.
Page 22
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- PRODUCT USAGE NOTICES Attachment to your Mobile Device To avoid damage to your Product and mobile device, attachment of the Product to your mobile device should be done with care, securing the locking knob with your fingers only. Do not use any external tools as too much pressure may mark or damage your mobile device.
Page 23
Therm-App MD User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------- WARNING Be careful when you clean the infrared lens. The lens has a delicate anti-reflective coating. Do not clean the lens too vigorously; this can damage the anti-reflective coating. WARNING The Product allows for field replacement of the lens. Exchanging the lens should be done with great caution, as after the removal of the lens the IR detector is exposed until the new lens is installed.
Need help?
Do you have a question about the MD and is the answer not in the manual?
Questions and answers