2. Auto standby test mode
Sets the auto standby timer to 4 minutes.
2.1. Operations
Press and hold the "SOURCE DIRECT" button for over 1 second while in version display mode.
"AutoStby Test" is displayed and then this unit enters the same mode as standard mode, except with an auto standby
timer.
L1
A u t o S t b y
L2
T e s t
Turn the power back on to cancel this mode.
3. Factory Initialization Mode
Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the PCB.
3.1. Operations
1. Press the power button to turn off the power.
2. While holding down buttons "ANALOG MODE" simultaneously, press the power button to turn on the power.
3. Press the power button to turn off the power.
3.2. Initialization item
No
Items
1
Input Source
2
DIMMER
3
Source Direct
4
Analog Mode
5
Auto Standby Mode
6
Protection
Descriptions
Information for the last selected input source
Dimmer setting
Source Direct (on/off) setting
Analog Mode (on/off) setting
Auto standby (on/off) setting
Information for the last detected protection
20
Default
CD
100%
Off
Off
E2 : On, JP : Off
NO PROTECT