Argo ULISSE ECO Operating Instructions Manual

Argo ULISSE ECO Operating Instructions Manual

Room air conditioner with remote condenser
Hide thumbs Also See for ULISSE ECO:

Advertisement

Room air conditioner with remote condenser
Condizionatore d'ambiente con condensatore remoto
Climatiseur avec condenseur a air exterieur - Klimagerät mit außengerät
Acondicionador de ambiente con condensador a distancia
Ar Condicionado com condensador remoto
INSTRUCÇÕES DE FUNCIONAMENTO
37.4256.044.00
01/2021
OPERATING INSTRUCTIONS
ISTRUZIONI D'USO
NOTICE D'UTILISATION
BEDIENUNGSANLEITUNG
INSTRUCCIONES DE USO
EN
IT
FR
DE
ES
PT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULISSE ECO and is the answer not in the manual?

Questions and answers

Summary of Contents for Argo ULISSE ECO

  • Page 1 OPERATING INSTRUCTIONS ISTRUZIONI D’USO NOTICE D’UTILISATION BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO INSTRUCÇÕES DE FUNCIONAMENTO Room air conditioner with remote condenser Condizionatore d’ambiente con condensatore remoto Climatiseur avec condenseur a air exterieur - Klimagerät mit außengerät Acondicionador de ambiente con condensador a distancia Ar Condicionado com condensador remoto 37.4256.044.00 01/2021...
  • Page 2: Table Of Contents

    CONTENTS SAFETY INSTRUCTIONS ................INSTALLATION LOCATION ................ELECTRICAL REQUIREMENTS ..............PRODUCT IDENTIFICATION ................MONITOR PANEL ..................AIR CONDITIONER INSTALLATION............... IMPORTANT ADVICE ..................USING THE REMOTE CONTROL UNIT ............REMOTE CONTROL UNIT ................HOW TO SET THE CLOCK ................COOLING/AUTOMATIC MODE ..............DEHUMIDIFYING MODE (DRY) ..............
  • Page 3: Installation Location

    INSTALLATION LOCATION ELECTRICAL REQUIREMENTS Before using the appliance WARNING • Check that the power supply at the location where the • Do not install this air conditioner where there are air conditioner is going to be used is 220/240 volt, single fumes or flammable gases, or in an extremely humid phase.
  • Page 4: Product Identification

    PRODUCT IDENTIFICATION 01. Infrared rays remote control unit 02. Monitor panel 03. Supply air deflector 4. Return air grille 5. Outdoor unit 06. Flexible tube 07. Air filter 08. Electric cable with plug 09. Service tube for condensate evacuation 10. Quick coupling cover MONITOR PANEL 1.
  • Page 5: Air Conditioner Installation

    AIR CONDITIONER INSTALLATION The air conditioner is made of two units interconnected by a flexible tube. The indoor unit must be placed in the room to be air conditioned, near a window, a balcony-door or a perimeter wall. The outdoor unit, that provides to the disposal of heat and condensation, must be located outside, on a window sill, on a balcony or hanged to the wall.
  • Page 6: Using The Remote Control Unit

    NOTE USING THE REMOTE CONTROL UNIT The remote control unit transmits signals to the indoor HOW TO INSTALL BATTERIES • Remove trhe lid in the rear part of the remote control unit each time you press a key and at any temperature unit.
  • Page 7: Remote Control Unit

    REMOTE CONTROL UNIT DISPLAY Information is displayed when the remote controller is switched on. HEATING MODE: not active on this unit FLAP: not active on this unit Operation mode I FEEL mode is active Cooling AUTO (remote controller sensor Dehumidification active) Night mode Automatic...
  • Page 8: How To Set The Clock

    HOW TO SET THE CLOCK DEHUMIDIFYING MODE (DRY) 1. Press for a few seconds the Timer button 1. Turn on the unit with the ON / OFF button Press the button 2. Press the button until the DEHUMIDIFYING symbol ARROWS appears on the display 3.
  • Page 9: Night Mode

    HOW TO SET SCHEDULES NIGHT MODE A) DELAYED TIMER This program is used to increase silence and comfort during This timer is used to start the unit (if it the night. is off) or to stop the unit (if it is on) after To activate the Night mode: a certain time, to set the delayed time.
  • Page 10: Parameters Setting

    PARAMETERS SETTING To access to the “Parameter menu”, long press “MODE/SET” from the main screen or from the OFF screen: (2 sec) The first parameter shown is P00. Press“UP”or“DOWN”to scroll the parameter list: When a parameter has been selected, long press “MODE/SET” to modify the value of the parameter. The value of the parameter starts blinking and SET symbol switches on: (2 sec) Press “UP”...
  • Page 11 (0.5 sec) Press “ON/OFF” to go back to main screen: Par. Parameter name Default Values Factory default reset 0 = No action 1 = Reset all remote control parameters to facto- ry default value Software version Software version of the remote controller Temperature scale 0 = °C (Celsius) 1 = °F (Fahrenheit)
  • Page 12: Adjusting The Air Flow Direction

    ADJUSTING THE AIR FLOW DIRECTION NOTE Power failure during operation. VERTICAL In the event of power failure, the unit will stop. When the Hold the end of the flap and move it up and down to adjust power is restored, the unit automatically restarts after 3 the vertical air flow.
  • Page 13: Accessories (Supplied On Request)

    AIR FILTER ACCESSORIES (SUPPLIED ON REQUEST) The air filter must be cheked at least once every two weeks OUTDOOR UNIT SUPPORT BRACKET KIT operation. Operation with a dirty filter always causes a lower efficency of the air conditioner and severe product damage. The filter is located at the back of the intake grille in the front It is possible to buy a support bracket kit for the installation of the air-conditioner and shall be removed from the upper...
  • Page 14: Tips For Energy Saving

    Trouble: the air conditioner does not run at all. TIPS FOR ENERGY SAVING Possible cause: 1. Power failure. DO NOT: 2. Leakage breaker tripped. Block the air intake and outlet of the unit. ● 3. Line voltage is too low. If they are obstructed, the unit will not work well, and 4.
  • Page 15 INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2012/19/EU At the end of its working life this equipment must not be disposed of as an household waste. It must be taken to special local community waste collection centres or to a dealer providing this service. Disposing of an electrical and electronic equipment separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be recovered and recycled to obtain significant savings in energy and resources.
  • Page 16 Via Alfeno Varo, 35 - 25020 Alfianello - BS - Italy Tel. +39 0331 755111 - Fax +39 0331 755501 www.argoclima.com...