E15 Cyclic Condenser Fan Error - arcelik BEKO COSMOS Service Handbook

Table of Contents

Advertisement

13.9.

E15 Cyclic condenser fan error

E15:
Speed
Condenser
Fan Error
Replace Condenser Fan
Sensitivity: Public
REFRIGERATOR
E15 Error flashes
Yes
Check cables connected to control card
DC Input-Output socket (KN10) pins 4,
5 and 6
If cables are disconnected, re-connect
them, turn on the refrigerator and check
Any errors on
display?
Yes
Remove the protective cover of the
compressor and check whether there is
anything preventing the rotation of the
condenser fan. If there is any problem,
fix it. Operate the refrigerator
Yes
If the error still being
displayed?
If the error is still being displayed,
replace the control board
Turn on the refrigerator
Operation is successful
118
SBS COSMOS
10.01.2014 / REV NO: 03
No
No