CLV 210...CLV 212 Bar Code Scanners

8. Setup

‡ Switch on the power supply 24 V DC for the CLV
The device switches to Reading mode automatically after the initialization procedure and self-test. The device
name and software version are displayed on the screen. The device then waits for a signal from the external
sensor to start the reading function.
You must switch to Percentage Evaluation mode to read a bar code without a sensor connected.
‡ Press the [ ESC ] key twice; select and confirm the "Percentage evaluation" menu item in the main menu.
‡ Hold the printed code sample in front of the reading window at a distance of approx. 120 mm (CLV 210,
CLV 211) or 70 mm (CLV 212). The scan line should cross the code bars at a right angle ( Fig. 7 ).
The device then evaluates 100 readings continuously and outputs the result on the screen as shown in Fig. 8 .
Line scanner
Fig. 7. Scan line/code assignment
Successful reading (Good read):
T T= _ _160 ms MG=_10% n=_1
C39 100% ST=0 CP=_46 CL=12 CA=_ _3 CS=109 CK=_ _1
UVWXYZ
where:
T T=
MG=
n=
C39=
100%=
ST=
CP=
CL=
CA=
CS=
CK=
UVWXYZ=
Fig. 8. Example: read results on the screen for a successful read
6
Duration of read interval
Mean time value of identification quality
Number of codes detected
Code type code 39
Identification quality
Read status (0= Good read)
Code position
Code length
Required scans
Code reliability
Code continuity
Code content
©
SICK AG
·
·
Division Auto Ident
Germany
Raster scanner
Code sample (Code 39):
module width 0.35 mm
·
All rights reserved
8 007 825/01-2002

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLV 210 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Clv 211Clv 212

Table of Contents