Installing and setting up PCU Base for IPC
10.3 Configuration of the system
10.3.3

Changing the name of the PC system

After installing PCU Base for IPC, a unique computer name is set. You can view and change
it in the Control Panel of the Service Desktop.
You can find the computer name in the Control Panel under Category "System", Section
"Computer name, domain and workgroup settings".
10.3.4

Setting the IP address and domain

The network settings in the state when delivered have been adapted for use with the
SINUMERIK system, and usually do not have to be changed.
If you want to distinguish your network configuration from the factory settings, you can adapt
them in the Windows Control Panel.
You can find the settings in the following menu (icon view):
● "Control Panel > Network and Sharing Center > View network connections"
Further information
You can adapt the network settings for backing up and restoring disk images in the
configuration of the Service Center (Page 199).
10.3.5

Configuring USB interfaces

The USB interfaces are activated in the as-delivered state of the PC system.
To prevent malicious software from entering the control or the system network via the USB
interfaces, you can deactivate the USB interfaces.
You can configure the USB interfaces on the Service Desktop via a command in the "Run"
dialog box in the prompt.
Procedure
To activate or deactivate the USB interfaces, enter the relevant command on the Service
Desktop in the "Run" dialog box or at the prompt:
Table 10-2
Factory setting:
Syntax:
Description:
184
Disabling USB interfaces with the "sc_usb disable" command
The USB interfaces are enabled in the delivery condition.
sc_usb disable [-minutes] [all] [HOSTS...]
● Without a time indication [-minutes], a permanent disable is set.
With time indication, the disable takes the time set in minutes.
● The disable may refer to all network nodes of the system network,
or a list of host names or IP addresses may be specified to which
the disable should apply.
MCU commissioning: NC, PLC, Drive
Commissioning Manual, 02/2020, A5E47437618B AB