Object 6124H: Ai Input Offset - GE BAKER HUGHES DPS 5000 Series Instruction Manual

Can bus pressure transducer
Hide thumbs Also See for BAKER HUGHES DPS 5000 Series:
Table of Contents

Advertisement

OBJECT DESCRIPTION
INDEX
Name
Object Code
Data Type
ENTRY DESCRIPTION
Sub-Index
Description
Access
PDO Mapping
Default Value
Sub-Index
Description
Data Type
Access
PDO Mapping
Default Value
Sub-Index
Description
Data Type
Access
PDO Mapping
Default Value
A.3.8 Object 6124h: AI Input Offset
This object defines the additional offset value for the analogue input channel. It is scaled in
physical unit of process value.
OBJECT DESCRIPTION
INDEX
Name
Object Code
Data Type
ENTRY DESCRIPTION
Sub-Index
Description
Access
© 2018 Baker Hughes, a GE company – All rights reserved.
6123
AI Input scaling 2 PV
Array
REAL32
000
number of entries
RO
No
0.0
001
AI Input scaling 2 PV 1
REAL32
RW
No
1.0
002
AI Input scaling 2 PV 2
REAL32
RW
No
1.0
6124
AI Input offset
Array
REAL32
000
number of entries
RO
Device Profile Segment
DPS 5000 Series Instruction Manual-English | 47

Advertisement

Table of Contents
loading

Table of Contents