REV 1.2
22/09/2020
Setting Name
wifi_on_gesture_count
wifi_on_gesture_time
wifi_on_gesture_initial_time
driving_state_timeout
Polarity and Input Style
The table below describes each setting
Setting Name
joystick_drive_forward
joystick_elevate_upward
joystick_neutral_move
elevate_polarity
drive_polarity
trigger_polarity
joystick_polarity
neutral_safe
driving_state_input
Bypass
Setting Name
test_cutout_state
EQUIPMENT SAFETY SYSTEMS
75 Naxos Way, Keysborough 3173 Victoria Australia
P: +61 3 8770 6555 E: support@eqss.com.au
Model6253 OverWatch™ Installation Manual
The number of times to cover and uncover the sensor
to enter Wi-Fi mode.
The timeout before OverWatch stops waiting for the
next part of the gesture in milliseconds
The timeout after startup before OverWatch stops
waiting for start of the gesture in milliseconds
Mode selection switch timeout
Direction of joystick to move EWP forward
Direction of joystick to move EWP upward
Direction of joystick that requires monitoring when in
neutral
Direction of signal logic
Direction of signal logic
Direction of signal logic
Direction of signal logic
Monitor when no drive mode set
Direct, timer based or separate joysticks
Test channel enabled for primary cutout
JLG R-Series
Installation Manual
Document # DO001237
Description
Description
Description
Default
3
3000
10000
7000
Default
forward
backward
forward
high
high
high
low
yes
direct
bypassed
|19 of
20|