Table 4-16. Address/Option Connector Configurations
Pin-set
Function
Upper
Lower
Configuration
Pin
1
Pin
1
1
I
Not
I
Power-
I
Used in multiuser systems to provide fauit tolerance. Do noi short this
Used
Fail
pm-set.
I
Reset/
Write
Protect
2
Gnd
Unit At-
Open: Enable Unit Attention.
tention
Shorted: Inhibit Unit Attention.
3
Gnd
SDTR
Open: Inhibit drive initiation of SDTR message.
Shorted: Enable drive initiation of SDTR message at Power-On and
Reset.
4
Gnd
Parity
Open: Inhibit parity checking.
Shorted: Enable parity checking.
5
Gnd
Auto
Open: Drive will not spin up until Initiator sends Start Unit
Spin-Up
Command.
Shorted: Drive will spin up automatically at Power-On.
6
Key: No pins.
7
Gnd
SCSI pin
Note: Pin-sets 7 and 8 have no effect if Sync Spindle Mode is
29
disabled.
8
SCSI pin Sync
7 Open, 8 Open: Nat Allowed.
29
Spindle
7 Open, 8 Shorted: Connects Sync Spindle line to SCSI pin 29.
When pin-set 8 is shorted, pin-set 7 must be open.
7 Shorted, 8 Open: Connects SCSI pin 29 to ground. Upper pin of
pin-set 8 is sync output in Master mode, or sync input in Slave
mode. When pin-set 7 is shorted, pin-set 8 must be open.
7 Shorted, 8 Shorted: Not Allowed.
9
Key: No pins.
1 Refers to the pin's orientation when the disk drive is viewed in the right-side-up position (see Figure 4-10, "FRONT
VIEW").
Configuration
4-33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents