Troubleshooting Guide for Growatt Inverters
Introduction
Due to a large amount of inappropriate outcome of troubleshooting on Growatt inverters,
our Australian office decide to compile a trouble shooting guide for Growatt installer
customers, which aims to resolve the problem in the initial stage of a technical diagnosis of
Growatt inverters and reduce the related cost of its process. We hope this document would
be helpful during a phone or email conversation when facing customer's technical enquiries.
1. Faulty code
Faulty code identifies the current states of the Growatt inverter. Warnings do not relate to a
fault. When a fault code with a number after it appears in the display, it indicates a fault on
the inverter or the system and is usually cleared through an orderly shutdown/re-set or a
self-corrective action performed by the inverter. See the faulty codes in the following table
and corresponding solutions.
The faulty code will display on the first line of the LCD screes of Growatt inverters, please ask
the customers to read this part for you and then you can figure out the phenomenon
accordingly by following sections.
1.1 No AC Connection
Cause: Somewhere disconnected from grid to inverter.
Error message
No AC Connection
1.2 AC V Outrange
Cause: The grid voltage is out of permitted range, or the inverter's voltage limit is incorrect.
MTL-S model
AC V
Non-MTL-S
Outrange
model
Description
No utility grid connected or
utility grid power failure
Purchased after 2017
Phone: 02 8065 1298
Email: australia@ginverter.com
Email:
ausupport@ginverter.com
www.ginverter.com
Solutions
1. Check if AC isolator /solar
main supply switch is on
2. Check if AC cables are
firmly and correctly
connected.
3. Contact Growatt to claim
warranty
Go to 1.2.1
Go to 1.2.3

Advertisement

loading
Need help?

Need help?

Do you have a question about the MTL-S and is the answer not in the manual?

Questions and answers

Summary of Contents for Growatt MTL-S

  • Page 1 See the faulty codes in the following table and corresponding solutions. The faulty code will display on the first line of the LCD screes of Growatt inverters, please ask the customers to read this part for you and then you can figure out the phenomenon accordingly by following sections.
  • Page 2 MTL-S model inverter If the inverter’s model is MTL-S, please find DIP switch at the bottom of inverter and set it to switch 1, 5 on while switch 2, 3, 4 off. Please refer to Fig 1.1 and Fig 1.2.
  • Page 3 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com Fig 1.2 1.2.2 voltage setting by knocking the inverter (for old model)please check the LCD display of the inverter below if the AC figure is lower than 262V or not. If yes, please follow the next steps.
  • Page 4 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com Knock to make the display become bright  Knock to item “Model: GTXXXXXX” Double www.ginverter.com knock to enter voltage range setting  Knock to change “QLD VMAX 255V”it to “Normal Vot range”...
  • Page 5 Shinebus. a) Change it remotely via Wi-Fi module monitoring If the inverter had been monitored by Growatt Wi-Fi module, then the setting can be changed via computer/laptop remotely. ShineServer set inverter tripping voltage Vmax Please follow the below steps to change the tripping voltage Vmax settings via ShineServer: (1) After signed in, click Plant ->...
  • Page 6 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com (4) Click button to apply the change. (5) Repeat to click button to apply the change again for 3 times.
  • Page 7 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com ShineServer: www.ginverter.com (1) Continue with the above process, on inverter setting page, click the page would then display an additional register option, as follows: (2) Choose the option “register”, and fill in the register number 112, and the set value.
  • Page 8 Change tripping voltage Vmax setting Please follow the below steps to change the tripping voltage Vmax setting: (1) Get ShineBus software from Growatt and install it to your laptop. Then connect inverter and laptop via RS232-to-USB cable. (2) Switch on the DC switch to power on inverter, and switch OFF the AC switch to disconnect inverter grid connection.
  • Page 9 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com (6) Fill in RS232-to-USB cable’s COM port number in “COM:” field. Set inverter’s COM address by knocking to inverter’s knock control panel (please refer to the manual), and fill the address in “InvAdd”...
  • Page 10 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com • Change 10 minutes average voltage 255v setting Please note, this option is only valid for new version inverters installed after 9, October, 2016.
  • Page 11 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com volt higher, thus is 265 volt. www.ginverter.com (3) Then click “Operate” to apply the change. Once inverter accepted, it would show “Set OK”...
  • Page 12 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com 1.4 AC F Outrange Cause: The grid frequency is out of permitted range, or the inverter’s frequency limits is incorrect.
  • Page 13 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com PV Voltage High The DC input voltage is Disconnect the DC switch www.ginverter.com exceeding the maximum immediately, check DC input...
  • Page 14 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com...
  • Page 15 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com...
  • Page 16 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com...
  • Page 17 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com Error codes identify a possible equipment failure, fault ot incorrect inverter setting or configuration. Tipically, error code can be cleared once the cause or fault is removed. Some of the error codes may indicate a fatal error and require you to contact the supplier or Growatt to replace it.
  • Page 18 Phone: 02 8065 1298 Growatt New Energy Australia Pty Ltd C1, 27-29 Fariola Street, Email: australia@ginverter.com Silverwater NSW 2128 Email: ausupport@ginverter.com www.ginverter.com Other faults In some cases, there is no message on the screen, please determine the fault by matching up with table of fault description below.