4.4.
Display codes
In the upper richt corner of the screen, a status code is shown that indicates the current status
of the control. Such a code can either be a status code or and error code.
The following table shows the possible status codes:
S0
Stopped
S1
Positioning
S2
Wait for ST low
S3
Wait for EOS
S4
Wait for UDP
S5
Wait for STEP high
S6
Wait for end of retract Waiting for end of retract when STEP is already high.
S7
Wait for safe X
The following table shows the possible error codes:
E1..
Internal error (1)
E21
Power supply failure
E23
Encoder 1 error
E24
Encoder 2 error
E53
Invalid parameters
E56
No movement on X-axis
E57
No movement on A-axis
E58
No movement on G1-axis
E59
No movement on G2-axis
E94
Internal error (1)
(1) If this error occurs, reboot the control. If the error persists, contact your machine supplier.
Waiting for the operator to press start while pump start is
high
Not all axes are in position yet
Waiting for STEP input falling edge
Wait for EOS, generated by potentiometer or BR
Wait for UDP, generated by potentiometer or STEP input
Waiting for STEP input rising edge
Waiting until X-axis is in safe area
Delem
V0208, 2.49
Need help?
Do you have a question about the DAC-360 and is the answer not in the manual?
Questions and answers