Electronic Controller

Introduction

The fridge is fitted with an electronic controller which is visible through a
cutout below the sign. The electronic controller is pre-programmed and
requires no initial setup or additional programming. SKOPE does not
recommend that the settings be changed unless it is absolutely necessary.
Temperature
The fridge temperature is set to stay between 1.5°C and 3.5°C. The setpoint
Setpoint
can be adjusted to other temperature ranges for specialist applications if
required (see below).
SKOPE do not recommend that the setpoint range be changed unless it is
absolutely necessary, and then only by small increments at a time.
To change the temperature setpoint range
Messages and
The following table explains messages and alarms that the electronic
Alarms
controller displays.

Messages and alarms

Operation
User Manual
1. Refer to the table below to determine the required temperature range.
Set Temperature range
0
0.0°C to 1.5°C
1
0.5°C to 2.5°C
2
1.5°C to 3.5°C
3
2.5°C to 4.5°C
4
3.0°C to 5.0°C
2. Press and hold the up and down buttons on the electronic controller for 3
seconds to unlock the controller.
3. Use the up and down buttons to scroll to the set number assigned to the
required temperature range, as shown in the table above.
4. Once the desired set is displayed, leave the controller for 5 seconds. The
display changes back to the cabinet internal temperature and the new set is
saved.
Display
Description
The cabinet internal temperature. The temperature is what the
sensor inside the fridge detects, and not necessarily the product
temperature. However, they may be very close depending on how
the controller is set to sense temperature.
Electronic controller lock indicator. On when the electronic controller
is locked. Off when the electronic controller is unlocked. Press and
hold the up and down buttons for 3 seconds to unlock the electronic
controller.
Compressor indicator. On when the compressor starts. Off when the
compressor stops.
Temperature sensor fault. This indicates a fault with the temperature
sensor. Arrange a service call.
SKOPE TCE1000N
Set Temperature range
5
3.5°C to 5.5°C
6
4.0°C to 6.0°C
7
5.0°C to 7.0°C
8
6.0°C to 8.0°C
-
-
9

Advertisement