19.10
Punching and nibbling
19.10.1
Signal overview
Figure 19-1
19.10.2
Signals to channel (DB21, ...)
DB21, ...
DBX3.0
Edge evaluation:
Signal state 1 or
This signal releases the punching strokes via the PLC.
edge change 0 → 1
1 signal: The stroke is locked, the NC may not trigger a punching stroke.
Signal state 0 or
0 signal: Punching stroke is available. As long as release is not set, the NC may perform a
edge change 1 → 0
punching stroke
DB21, ...
DBX3.1
Edge evaluation:
Signal state 1 or
This signal enables the triggering of a single stroke in manual mode.
edge change 0 → 1
1 signal: Manual stroke is performed.
Signal state 0 or
0 signal: No effect.
edge change 1 → 0
Extended Functions
Function Manual, 01/2008, 6FC5397-1BP10-3BA0
PLC interface signals for "Punching and nibbling"
No stroke enable
Signal(s) updated:
Manual stroke initiation
Signal(s) updated:
NC/PLC interface signals (Z2)
19.10 Punching and nibbling
1055