Advertisement

TUE
9:30
2
AM
ROOM TEMP
18
.
c
5
MENU
OK
LUNA STAT THERMOSTAT MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LUNA STAT and is the answer not in the manual?

Questions and answers

Summary of Contents for Ambiente LUNA STAT

  • Page 1 9:30 ROOM TEMP MENU LUNA STAT THERMOSTAT MANUAL...
  • Page 2: Table Of Contents

    CONTENTS LCD display What is the Luna Stat Change/check Installation procedure temperature Setting program mode Setback temperature Programmable mode Features available on all LCD display program modes Setting the clock Frost protection Change/check Setting the hold mode temperature Keypad lock...
  • Page 3: What Is The Luna Stat

    WHAT IS THE LUNA STAT The Luna Stat is a multi-function thermostat for underfloor heating, radiators or any other form of heating where multifunction temperature control is required. The Luna Stat consists of two main modes 1. Standalone programmable/non-programmable thermostat...
  • Page 4 1. PROGRAMMABLE/NON - PROGRAMMABLE THERMOSTAT The Luna Stat operates by itself as independent control to the rest of the heating system as a thermostat in either programmable or non/programmable operation. A. Non Programmable – operates as a simple thermostat where the temperature is held at the set point continuously.
  • Page 5 2. SET BACK THERMOSTAT WITH CENTRAL PROGRAMMER The Luna Stat operates as temperature control on a room by room basis in conjunction with a single programmer (supplied separately) providing central timed control for larger areas or whole houses. The Luna Stat is set to non-programmable and maintains the temperature at the set point whilst the programmer is on.
  • Page 6: Installation Procedure

    INSTALLATION PROCEDURE Care should be taken on where the Luna Stat is installed, as being the ultimate control of your heating it is important that it is not installed near any secondary hot or cold sources. The Luna Stat should be installed at chest/eye level (approximately 1.5 metres) and where it will receive an even reading of the temperature of the room.
  • Page 7 Luna Stat. Step 2 Step 4 Ensure that the front (Screen) Clip the front on to the back...
  • Page 8: Setting Program Mode

    SETTING YOUR PROGRAM MODE SELECTION This Luna Stat has been set by default to a Programmable thermostat in 5+2 day programming (Weekdays + Weekend). To change between programmable, non-programmable and set back thermostat follow these steps. 1. Press MENU till the ‘SET SETUP’ main menu item flashes.
  • Page 9: Programmable Mode

    PROGRAMMABLE MODE ( 5+2 AND 7 DAY ) 9:30 ROOM TEMP MENU...
  • Page 10: Lcd Display

    LCD DISPLAY HOLD LEFT HOLIDAY LEFT 88:88 PERIOD ROOM TEMP FLOOR TEMP COPY TO OVERRIDE CLOCK HOLIDAY SCHEDULE SETUP HOLD...
  • Page 11 LCD DISPLAY 1. Day of the week – Displays the current day. 2. Temperature unit – Degrees Celsius ( C) or Fahrenheit ( 3. Hold Left indicator. – Displays when the HOLD FOR function is active along with the hours of hold remaining. 4.
  • Page 12 LCD DISPLAY 11. SET – Displays when any program or parameter is being changed. 12. Temperature – Displays the current sensor temperature. 13. Frost Shield – Displays when the thermostat is in frost protection mode. 14. Flame Symbol – Displays when the thermostat is calling for heat.
  • Page 13: Setting The Clock

    SETTING THE CLOCK To set/change the clock and day follow these steps. This is not applicable if the thermostat is in non-program mode. 1. Press MENU so the ‘SET CLOCK’ main menu item flashes. 2. Press OK to confirm. The current hour will flash 3.
  • Page 14: Change/Check

    CHANGE/CHECK THE TEMPERATURE SETTING To set/change the temperature (temporary override) follow these steps. Note, this only changes the temperature until the next program time. 1. Press once to view the current temperature setting. 2. Press repeatedly to change the thermostat in increments of 0.5 3.
  • Page 15: Schedule And Comfort

    SCHEDULE AND COMFORT SETTINGS The Luna Stat comes pre-programmed with comfort levels set. These factory default settings are: Week Day and Weekend – 5/2 day programming Mon-Fri 5.30 - 20 C 8.00 - 16 C 16.00 - 20 C 22.00 - 16 Sat-Sun 6.30 - 20...
  • Page 16 Note: Selected days are shown without flashing. d. Press OK to save the copy and Luna Stat returns to main menu. 13. Repeat steps 2-12 to set and/or copy further days. 14. Press MENU to save the change and the button to return to the home screen.
  • Page 17: Setting The Holiday Mode

    SETTING THE HOLIDAY MODE To set/change the Holiday mode follow these steps. (This is not applicable in non-programmable mode.) 1. Press MENU till the ‘SET HOLIDAY’ main menu item flashes. 2. Press OK to confirm. The ‘HOLIDAY LEFT’ symbol will show and the number of days will flash.
  • Page 18: Optimum Start

    OPTIMUM START The Luna Stat will typically turn the heating on at the time set in the program. With the optimum start feature enabled the Luna Stat will display a flashing symbol and turn the heating on beforehand in order to reach the required temperature for the time set.
  • Page 19: Non-Programmable Mode

    NON - PROGRAMMABLE MODE ROOM TEMP MENU...
  • Page 20: Lcd Display

    LCD DISPLAY HOLD LEFT 88:88 ROOM TEMP FLOOR TEMP SETUP HOLD...
  • Page 21 LCD DISPLAY 1. Temperature unit – Degrees Celsius ( C) or Fahrenheit ( 2. Hold Left indicator – Displays when the HOLD FOR function is active along with the hours of hold remaining. 3. Room/Floor Temperature – Indicates the current sensor set up and point of temperature measurement.
  • Page 22: Change/Check

    CHANGE/CHECK THE TEMPERATURE SETTING To set/change the temperature follow these steps. 1. Press once to view the current temperature setting. 2. Press repeatedly to change the thermostat in increments of 0.5 3. Press OK to save the new temperature and return to the home screen.
  • Page 23 NON - PROGRAMMABLE SETBACK MODE ROOM TEMP...
  • Page 24: Lcd Display

    LCD DISPLAY HOLD LEFT 88:88 ROOM TEMP FLOOR TEMP HOLD SETUP...
  • Page 25 4. Time – Displays the current hold time left when in hold mode. 5. Setback – Is displayed when Luna Stat is in temperature set-back. 6. Key pad Lock – Displays when the key pad is locked.
  • Page 26: Change/Check

    CHANGE/CHECK THE TEMPERATURE SETTING To set/change the temperature follow these steps. 1. Press once to view the current temperature setting. 2. Press repeatedly to change the thermostat in increments of 0.5 3. Press OK to save the new temperature and return to the home screen.
  • Page 27: Setback Temperature

    SETBACK TEMPERATURE The Luna Stat operates a built in temperature set-back when a timer/ programmer is connected to the Luna stat. This set back is adjustable using the following steps. 1. Press MENU till the ‘SET SETUP’ main menu item flashes.
  • Page 28: Features Available On All Program Modes

    FEATURES AVAILABLE ON ALL PROGRAM MODES FROST PROTECTION To set the thermostat in frost protection mode press the button. The symbol will display indicating that the thermostat is in frost mode and set to a lower temperature – factory default of 12...
  • Page 29: Setting The Hold Mode

    SETTING THE HOLD MODE To set/change the Hold mode follow these steps. 1. Press MENU till the ‘SET HOLD’ main menu item flashes. 2. Press OK to confirm. The ‘HOLD LEFT’ symbol will show and the number of hours flash. 3.
  • Page 30: Keypad Lock

    KEYPAD LOCK The Luna Stat keypad can be locked to prevent any accidental adjustment or tampering of the thermostat. Press and hold until the symbol shows. Keypad is now locked. Press and Hold until the symbol disappears to unlock the Luna Stat.
  • Page 31: Floor Limit Protection

    FLOOR LIMIT PROTECTION If a floor sensor has been installed with the Luna Stat this enables a floor limit temperature to be set and controlled through the optional features, explained on pages 33-35. This will stop the heating when the floor temperature reaches this point and will show the symbol.
  • Page 32: Factory Reset

    FACTORY RESET Should the Luna Stat need to be reset to factory default settings follow these steps. Press and Hold the Button to turn the Luna Stat off. Press and hold and . The Luna Stat will display all icons on the screen for 2...
  • Page 33: Optional Features

    In many cases these need not be adjusted. Feature 01 – Sensor Selection: The Luna Stat has the option of using its own built in air sensor (default), a remote air sensor, floor sensor or a combination of these sensors for floor limit protection when both an air and floor sensor are used.
  • Page 34 OPTIONAL FEATURES EXPLAINED Feature 06 – On/Off Status: The Luna Stat can be set to come on or stay off when power is turned on to the thermostat. Default is auto on/off from last power off. Feature 07 – Temperature Calibration: The Luna Stat has the option to adjust the sensor calibration by +/- 10 C in 0.5...
  • Page 35 This can be set from 00 – 15 minutes. Default is 00. Feature 12 – Optimum Start: The Luna Stat has the option to set an optimum start of up to 3 hours, see page 18 for more detail.
  • Page 36 CHANGING THE OPTIONAL FEATURES To change the optional features on the Luna Stat follow these steps,selecting the required feature number and setting value. 1. Press MENU till the ‘SET SETUP’ main menu item flashes. 2. Press OK to confirm. The small digits display the feature number, the large digits display the setting value for the feature.
  • Page 37: Optional Features Table

    OPTIONAL FEATURE TABLE Feature Description Setting No. Sensor Selection 00=Internal air sensor (Default) 01=Remote air sensor 02=Remote floor sensor 03=Internal air and remote floor sensor 04=Remote air and remote floor sensor Time Format 12=12 hour, 24=24 hour (default) Temperature Format C (Default), 01= Frost Protection when off 00=Enabled (Default)
  • Page 38 OPTIONAL FEATURE TABLE Optimum Start 00 ~ 03 hours (Default = 00) Rate of Change Information only, non-adjustable Floor Temperature Limit C ~ 60 C (68 F ~ 140 (Default =28 Setback Enable 00=OFF (Default) 01=ON Setback Temperature C ~ 5 C (5 F ~ 9 F) (Default =4...
  • Page 39: Error Codes

    Temperature higher than Move thermostat to a cooler area Check for influence from external heat source Check Luna Stat calibration Temperature lower than 0 Move thermostat to warmer area Check for influence from draught or external cooling...
  • Page 40: Wiring Diagrams

    WIRING DIAGRAMS Wiring Diagrams Luna Stat basic wiring diagram with switch live for heat item. Luna Stat basic wiring diagram with switch live for heat item. This product must only be installed in accordance with local installation regulations and by a qualified electrician...
  • Page 41 WIRING DIAGRAMS Luna Stat wiring diagram with volt free switching for heat item. Wiring Diagrams Luna Stat wiring diagram with volt free switching for heat item. This product must only be installed in accordance with local installation regulations and by a qualified electrician...
  • Page 42 WIRING DIAGRAMS Luna Stat wiring diagram connecting to UH8 Wiring Centre. Wiring Diagrams Luna Stat wiring diagram connecting to UH8 Wiring Centre. This product must only be installed in accordance with This product must only be installed in accordance with...
  • Page 43 Luna Stat basic wiring diagram in setback mode connecting to Wiring Diagrams UH8 Wiring Centre. Luna Stat basic wiring diagram in setback mode connecting to UH8 Wiring Centre. This product must only be installed in accordance with local installation regulations and by a qualified electrician...
  • Page 44 Need more information or advice? Contact our team of highly trained experts today. 01707 649 118 info@ambienteufh.co.uk www.ambienteufh.co.uk LUNA STAT THERMOSTAT MANUAL...