Hydrotek 5000EM Series Operation & Maintenance Manual

Hydrotek 5000EM Series Operation & Maintenance Manual

Faucet

Advertisement

Sensor Faucets and Flush Valves
OPERATION & MAINTENANCE MANUAL
5000EM Series Faucet
www.hydrotekintl.com
5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807
Phone (800) 922-9883 | Fax (866) 670-5580

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5000EM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hydrotek 5000EM Series

  • Page 1 Sensor Faucets and Flush Valves OPERATION & MAINTENANCE MANUAL 5000EM Series Faucet www.hydrotekintl.com 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 | Fax (866) 670-5580...
  • Page 2 AC or Batt ery Powered Sensor Operated Faucet Sensor Faucets and Flush Valves The 5000EM Series faucet is an elegant piston operated sensory faucet that provides a vandal resistant, no touch lavatory soluti on with hot/cold mixing and manual on/ off adjustments that promotes bett er hygiene and energy savings.
  • Page 3 Hydrotek Automati c Faucets 5000EM Series Deck Mounted / Non-mixing Meets ANSI/ASME A112.18.1 M-1989 Operati on: A conti nuous, invisible beam is emitt ed from the sensor. The faucet is acti vated by placing hands under the spout within the eff ecti ve range of the beam.
  • Page 4: Installation Instructions

    H-5000EM AC Powered Sensor Operated Mixing Faucet Installation Instructions...
  • Page 5 IMPORTANT:DO NOT use abrasives, acids or cleaning fluids 6. Aerator 17. V.R. Access Cover to clean the Hydrotek Faucet as they may dull the luster and 7. V.R. Screw, Top Cover 18. Lock –V.R. Access Cover attack the chrome or special finishes. use only soap and water 8.
  • Page 6: Troubleshooting Guide

    IMPORTANT: Periodic maintenance is required for smooth and trouble-free operation of this faucet. For service and inquiry about available repair kits, please call Hydrotek Technical Support at (800) 922- 9883.
  • Page 7: Maintenance Tasks

    4. Loosen the two screws holding the Battery Holder/ Control Module and remove it. 5. Install the new Battery Holder/Control Module ensuring the sensor eye is fitted correctly to the faucet body. Solenoid Module For further questions, please call Hydrotek Technical Support at (800) 922-9883.
  • Page 8: Assembly Parts

    5000EM Series 5000EM Series Sensor Operated Mixing Faucet Assembly Parts Sensor Faucets and Flush Valves Parts Breakdown No Part Number Description HCE-004 Solenoid Module HCE-019 Solenoid Coil Control Module HCE-018A/B A=AC, B=Battery HCE-028 Temp. Adjuster Rod HCE-029 Temp. Handle Assembly...