1 Alarms
Definitions:
Reactions:
Remedy:
Program Continuation:
300404
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300405
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-546
The version number of the drive software (FDD/MSD) must correspond to the version
number stored in the drive machine data because the MD files for different software ver-
sions are not compatible.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. After exchanging the drive
software, the drives must be installed and started up again. Any MD files that were saved
by the control running under the old version must no longer be used. The old data can be
saved with the installation and start-up tool and this data can also be used again.
Clear alarm with the RESET key in all channels. Restart part program.
Axis %1 drive %2 drive MD contains different drive number
%1 = NC axis number
%2 = Drive number
In the drive MD file loaded in a drive there is a drive number which does not correspond to
this drive.
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Files with drive data for a particular drive number must not be copied to another drive.
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Axis %1 drive %2 unknown drive alarm, code %3
%1 = NC axis number
%2 = Drive number
%3 = Service number
The service number signaled by the drive is not implemented in the NCK. It cannot be
assigned to any alarm number.
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Reinitialization of the drive
required.
The search for the precise cause of error can only be performed by the development
team. The displayed error codes are always needed for this. (contact SIEMENS AG, Sys-
tem Support for A&D MC products, Hotline (Tel.: see alarm 1000).
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
10.04