Siemens SINUMERIK 840D Diagnostics Manual page 265

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

10.04
Definitions:
Reactions:
Remedy:
Program Continuation:
16793
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16794
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16795
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16796
Parameters:
 Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
For the specified axis/spindle, more master axes/spindles have been defined than are
allowed.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 coupling of axis %3 prohibits transformation change
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
The specified axis is a slave axis in a transformation grouping. When the coupling is
switched on, the transformation cannot be changed to another one.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program. Switch off coupling(s) of this axis before changing transformation or
do not change the transformation.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 coupling of axis/spindle %3 prohibits reference point
approach
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
The specified axis is a (gantry) slave axis and cannot therefore approach the reference
point.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program. Switch off coupling(s) of this axis before reference point approach or
do not reference. A gantry slave axis cannot reference for itself.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 string cannot be interpreted
%1 = Channel number
%2 = Block number, label
A coupling has been switched on in which a non-interpretable string has been written (e.g.
block change behavior).
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 coupling not defined
%1 = Channel number
%2 = Block number, label