CorroVenta K3 HP B User Manual

CorroVenta K3 HP B User Manual

Condensing dryer
Hide thumbs Also See for K3 HP B:

Advertisement

Quick Links

CONDENSING DRYER
K3 HP B
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K3 HP B and is the answer not in the manual?

Questions and answers

Summary of Contents for CorroVenta K3 HP B

  • Page 1 CONDENSING DRYER K3 HP B USER MANUAL...
  • Page 2: Table Of Contents

    Water bucket ............................. 12 Maintenance and service ........................13 Inspection and cleaning of process air filters, water filters and cleaning of bucket ......13 Accessories and consumables ......................14 Fault tracing ............................15 Technical data ............................15 © Corroventa Ltd. 2020.04 1 (15)
  • Page 3: Area Of Use

    K3 HP B is equipped with a bucket that condensation water is routed to, which must be emptied manually. It is also possible to connect a hose to the bucket and then route the water to a floor drain for example.
  • Page 4: Manufacture Directive

    Manufacture directive Condensing dryer K3 HP B is tested according to applicable directives and standards by Intertek. The dryer is CE labelled. Disclaimer Incorrect installation and/or incorrect use can cause damage to property as well as injury. • The manufacturer assumes no liability for property damage or injury incurred as a result of •...
  • Page 5: Safety Information

    20. The dryer must not be used with accessories other than those described in this manual or approved by Corroventa Avfuktning AB. The dehumidifier must be placed at a distance of at least half (0.5) meters from the walls and ceilings to ensure that the air can circulate.
  • Page 6: Relative Humidity And Its Impact On Materials

    At 100% RH the air is saturated, and the moisture falls in the form of small water droplets. Steel corrodes at 60% RH and at 70% RH there is a risk of mould. A rule of thumb is that 50% RH is a good climate for most materials. © Corroventa Ltd. 2020.04 5 (15)
  • Page 7 As the graph above shows, condensing dehumidifiers are used in hot and humid spaces if room drying is required. © Corroventa Ltd. 2020.04 6 (15)
  • Page 8: This Is How The Dryer Works

    The dry and hot air is then blown into the premises again. For optimal operation, machine defrosting is demand controlled and is only activated when the temperature and humidity conditions are such that frost forms on the cooling coil. © Corroventa Ltd. 2020.04 7 (15)
  • Page 9: Overview, Controls And Connections

    Overview, controls and connections The images below show Corroventa K3 HP B with its external parts and controls. Folding handle/ Carry handle Process air filter Dry air connectors for hose connection Durable feet that Bucket allow stackability and prevent damage to surfaces.
  • Page 10: Alarm/Indicator Lamp

    If the alarm remains, contact a service technician. Insufficient Cooling capacity Internal fault. Disconnect the machine from power for a few minutes and restart again. If the alarm remains, contact a service technician. © Corroventa Ltd. 2020.04 9 (15)
  • Page 11: Electrical Connection

    Electrical Connection The machine is connected to the earthed 230V/50Hz socket. K3 HP B can be connected to a 10A, max 16A, fuse. Electronic control delays the start approx. 2 minutes. Starting and operating Operating range humidity: 30-100% RH •...
  • Page 12: Transportation

    If the machine toppled over during transportation, the machine must stand upright for at least 30 minutes prior to starting. The machine must be transported upright and must always be upright during operation. Transport must be carried out in accordance with local regulations. © Corroventa Ltd. 2020.04 11 (15)
  • Page 13: Storage

    Storage K3 HP B can be stored stacked on top of each other as shown below, thus saving floor space. The machine must always be stored upright, frost-free and in a ventilated area without sources that may cause sparking or near flammable substances.
  • Page 14: Maintenance And Service

    Inspect or clean water filters annually or more frequently if the machine is used in dirty environments, replace if necessary. Follow the instructions below: Before starting any maintenance and servicing, the dryer must be unpowered. Remove the plug from the wall socket. © Corroventa Ltd. 2020.04 13 (15)
  • Page 15: Accessories And Consumables

    Reinstall the water filter carefully. Accessories and consumables The following parts are available as accessories and consumables for K3: Part number Designation 01100 Hygrostat HS1-5 (5m cable) 1003146 Condensation water filter 1002412 Process air filter © Corroventa Ltd. 2020.04 14 (15)
  • Page 16: Fault Tracing

    Technical data K3 HP B Operating range, RH, % 30-100% Operating temperature range, °C +9 to +38 Rated output, W Actual output, W Dehumidification, max., litres per 24 hours...