Summary of Contents for CorroVenta K3 HP

  • Page 1 CONDENSING DRYER K3 HP USER MANUAL...
  • Page 2: Table Of Contents

    Storage .............................. 12 Maintenance and service ........................13 Inspection and cleaning process air filters, water filters and cleaning collection receptacles ..13 Accessories and consumables ......................15 Fault tracing ............................15 Technical data ............................16 © Corroventa Ltd. 2020.04 1 (16)
  • Page 3: Area Of Use

    User instructions K3 HP Area of use Condensing drier K3 HP is primarily intended for professional use. It has been specially developed for use in occupied areas in event of urgent damage or where it is difficult to eliminate the humid air from an adsorption dehumidifier.
  • Page 4: Manufacture Directive

    Manufacture directive Condensing dryer K3 HP is tested according to applicable directives and standards by Intertek. The dryer is CE labelled. Disclaimer • Incorrect installation and/or incorrect use can cause damage to property as well as injury. • The manufacturer assumes no liability for property damage or injury incurred as a result of failing to follow these instructions, the machine being used for purposes other than those intended or failure to observe these warnings.
  • Page 5: Safety Information

    20. The drier must not be used with accessories other than those described in this manual or approved by Corroventa Avfuktning AB. 21. The dehumidifier must be placed at a distance of at least half (0.5) meters from the walls and ceilings to ensure that the air can circulate.
  • Page 6: Relative Humidity And Its Impact On Materials

    At 100% RH the air is saturated, and the moisture falls in the form of small water droplets. Steel corrodes at 60% RH and at 70% RH there is a risk of mould. A rule of thumb is that 50% RH is a good climate for most materials. © Corroventa Ltd. 2020.04 5 (16)
  • Page 7 As the graph above shows, condensing dehumidifiers are used in hot and humid spaces if room drying is required. © Corroventa Ltd. 2020.04 6 (16)
  • Page 8: How The Drier Works

    The dry and hot air is then blown into the premises again. For optimal operation, machine defrosting is demand controlled and is only activated when the temperature and humidity conditions are such that frost forms on the cooling coil. © Corroventa Ltd. 2020.04 7 (16)
  • Page 9: Overview, Controls And Connections

    Overview, controls and connections The images below show Corroventa K3 HP with its external parts and controls. Condensation water hose Durable feet that allow stackability and Process air filter prevent damage to surfaces. Folding handle as well as cable/ condensation water hose...
  • Page 10: Alarm/Indicator Lamp

    If the alarm remains, contact a service technician. Insufficient Cooling capacity Internal fault. Disconnect the machine from power for a few minutes and restart again. If the alarm remains, contact a service technician. © Corroventa Ltd. 2020.04 9 (16)
  • Page 11: Electrical Connection

    Electrical connection The machine is connected to the earthed 230V / 50Hz socket. K3 HP can be connected to a 10A, max 16A, fuse. Electronic control delays the start approx. 2 minutes. Starting and operating • Operating range humidity: 30-100 %RH •...
  • Page 12: Transportation

    If the machine toppled over during transportation, the machine must stand upright for at least 30 minutes prior to starting. The machine must be transported upright and must always be upright during operation. Transportation must be carried out in accordance with local regulations. © Corroventa Ltd. 2020.04 11 (16)
  • Page 13: Storage

    Storage K3 HP can be stored stacked on top of each other as shown below, thus saving floor space. The machine must always be stored upright, frost-free and in a ventilated area without sources that may cause sparking or near flammable substances.
  • Page 14: Maintenance And Service

    Inspect or clean water filters annually or more frequently if the machine is used in dirty environments, replace if necessary. Follow the instructions below: Before starting any maintenance and servicing, the drier must be unpowered. Remove the plug from the wall socket. © Corroventa Ltd. 2020.04 13 (16)
  • Page 15 This facilitates cleaning and access to the overflow sensor. Then start reassembling the machine: 1. Clip the cover onto the collection receptacle, if removed. Ensure that the overflow sensor moves freely and easily. © Corroventa Ltd. 2020.04 14 (16)
  • Page 16: Accessories And Consumables

    5. Carefully replace the air filter, ensure it is inside the support edge and seals tightly. Accessories and consumables The following parts are available as accessories and consumables for K3 HP: Part number Designation 01100 Hygrostat HS1-5 (5m cable)
  • Page 17: Technical Data

    Technical data Type LAF 50 LAF 50E LAF 50E2 LAF 100 LAF 100E LAF 150 LAF 150E K3 HP Operating range, RH, % 30-100 % Operating temperature range, °C +9 to +38...
  • Page 18 Our products are compact, effective, ergonomic and energy efficient. In emergency situations and during flooding, Corroventa’s customers have access to one of the largest rental CORROVENTA LTD parks in Europe. We have sales offices and machine depots in several locations Unit 29, Irlam Business Centre, Irlam, Manchester throughout Europe.

Table of Contents