Label
Cause
E4
Protective guard alarm
E7
Encoder sealer M1
E8
Encoder feeder M2
E9
Jam sensor
E10
Zeroing sensor
Sealer M1 not found
E11
Temperature of the cross
sealer not within normal
range
E12
Temperature of one of
the longitudinal sealers
not within normal range
E13
The temperature of the
cross sealer does not
increase when heated
E14
The temperature of one
of the longitudinal
sealers does not
increase when heated
Possible measures
•
Micro-switch of the front protective guard is open, close the
carter
•
Check connection
•
The encoder of sealer M1 is not counting, check that the sealer
is not blocked mechanically
•
Check the micro-switch of the protective guard
•
Check connection
•
The encoder of feeder M2 is not counting, check that the sealer
is not blocked mechanically
•
Check connection
•
Airpads jammed, check the operating and machine parameters
•
Check the distance of the sensors relative to the light spot
•
Check connection
•
The zero sensor of the sealer did not turn on,
check the position and connection
•
Check the connection of the thermocouple of the cross sealer
•
Make sure that all the thermocouples are insulated
•
Check the connection of the thermocouple of the longitudinal
sealers
•
Make sure that all the thermocouples are insulated
•
Check the connection of the thermocouple of the heating
element of the cross sealer
•
Check the connections of the thermocouples of the heating
elements of the longitudinal sealers