Label
Cause
E4
Protective guard alarm
E7
Encoder sealer M1
E8
Encoder feeder M2
E9
Jam sensor
E10
Zeroing sensor
Sealer M1 not found
E11
Temperature of the cross
sealer not within normal
range
E12
Temperature of one of
the longitudinal sealers
not within normal range
E13
The temperature of the
cross sealer does not
increase when heated
E14
The temperature of one
of the longitudinal
sealers does not
increase when heated
Possible measures
Micro-switch of the front protective guard is open, close the
carter
Check connection
The encoder of sealer M1 is not counting, check that the sealer
is not blocked mechanically
Check the micro-switch of the protective guard
Check connection
The encoder of feeder M2 is not counting, check that the sealer
is not blocked mechanically
Check connection
Airpads jammed, check the operating and machine parameters
Check the distance of the sensors relative to the light spot
Check connection
The zero sensor of the sealer did not turn on,
check the position and connection
Check the connection of the thermocouple of the cross sealer
Make sure that all the thermocouples are insulated
Check the connection of the thermocouple of the longitudinal
sealers
Make sure that all the thermocouples are insulated
Check the connection of the thermocouple of the heating
element of the cross sealer
Check the connections of the thermocouples of the heating
elements of the longitudinal sealers
11