SERVICE-MANUAL AIRPAD - MACHINE AP210 Manual for authorized resellers and service points INDEX PAGE PRELIMINARY REMARKS WORKING PAGES Working page 1............. . 2 Working page 2.
PRELIMINARY REMARKS The AP210 has been designed to be used easily by the operator. Therefore, the operator can only change the number of airpads which are programmed by following the procedure described in paragraph 13.5 of the Instructions for Use and Maintenance.
Push the left right arrow to scroll through the other working pages. Working page 2 Page 2 shows: • length of airpad, • number of airpads programmed. Procedure for changing parameters: Push The following screen appears: Entering the password allows changing the programmed values (except for the same password given in the preliminary remarks) by pushing the buttons until the parameter to be changed is highlighted, confirm with the button...
In order to change the operating mode refer to the procedure described in paragraph 2.2. WORKING PAGE IN "MANUAL" The AP210 allows to activate the motors manually by opening the page "manual". From the initial screen, or from the working pages if the machine is in stand by.
With the button the motor of the cross sealer is activated anti-clockwise, only if the protective guard is closed. Releasing the button stops the motor. If the protective guard is open, the downward arrow disappears from the display and the cross sealer cannot be activated. With the button film advance is activated (only when the sealer is sufficiently open, otherwise, the arrow disappears from the display).
Page 6
Index Signal/function Polarity IN 8 Micro-switch protective guard ON = protective guard open, OFF= protective guard closed IN 9 Proximity presence hopper ON = proximity turned on (hopper present) IN 10 Photocell presence material/hopper full ON = material in front of photocell IN 11 IN 12 Proximity position at the bottom of the...
Page 7
Operational page of the PID of sealer temperature (first temperature series) Operational page of the PID of sealer temperature (second temperature series) Compensation of the ambient temperature Calibration data Jog page: It is possible operate on this page only with machine in standby. With the buttons select engine/device to activate, press for activation.
• M2 forward • M2 backward • M3 forward • M4 forward • M5 ON (extraction fan) • R1 ON (cross heating element) • R2 ON (longitudinal heating element) • Display of frequency, amount and temperatures MACHINE PARAMETERS PAGE This is accessed by pushing Here, all the parameters are assembled which remain operational for all formulas.
PAGES FOR PARAMETER SETTINGS Turn on by pushing ; the parameters that differentiate the 9 formatting recipes are listed on these pages and may be modified; There are two pages for each format; the first line shows the index (1-9) of the programme and the page (1/2 or 2/2) On the first screen And on the second screen.
The following settings for parameters are shown: Page Parameter Unit Description Page 1/2 Name Alphanumeric Name of the setting % Spd.M1 % (1-100) Max. velocity of sealer % Spd.M2 % (1-100) Max. velocity of transporting film % Spd.M3 % (1-100) Max.
Page 11
Label Cause Possible measures Protective guard alarm • Micro-switch of the front protective guard is open, close the carter • Check connection Encoder sealer M1 • The encoder of sealer M1 is not counting, check that the sealer is not blocked mechanically •...
Need help?
Do you have a question about the AP210 and is the answer not in the manual?
Questions and answers