Drummond 56599 Owner's Manual & Safety Instructions

Drummond 56599 Owner's Manual & Safety Instructions

1/4 hp submersible utility pump with fully automatic on/off operation

Advertisement

Owner's Manual & Safety Instructions
Save This Manual
operating, inspection, maintenance and cleaning procedures. Write the product's serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference.
1/4 HP
SUBMERSIBLE
UTILITY PUMP
WITH FULLY AUTOMATIC
ON/OFF OPERATION
Do not return
pump to the store.
Call 1-844-416-9141
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
©
Copyright
2019 by Harbor Freight Tools
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Keep this manual for the safety warnings and precautions, assembly,
Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
®
. All rights reserved.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
19i
56599

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 56599 and is the answer not in the manual?

Questions and answers

Di
February 15, 2025

How do I attach the strainer? It doesn’t seem to line up correctly with the latches.

2 comments:
Mr. Anderson
February 15, 2025

To attach the strainer for Drummond part number 56599, align the pump base to the Debris Strainer using the Switch Housing as a guide. Guide the back of the pump (opposite the discharge) into the strainer. If it does not line up correctly with the latches, adjust the pump’s position slightly and rotate it until it latches in place. Ensure the strainer is properly secured before use.

This answer is automatically generated

Vicky Bell
February 23, 2025

We can’t get the debris stainer off the latches don’t seem to work

Darrell
February 19, 2025

does the pump start automaticly when you connect the electrical supply ?

1 comments:
Mr. Anderson
February 19, 2025

No, the Drummond pump with part number 56599 does not start automatically when connected to the electrical supply. It is fully automatic in operation, but it only starts when the water level is over 2 inches. The built-in control system detects water and then starts the pump. If the water level is not over 2 inches, the pump will not start.

This answer is automatically generated

Darrell
February 19, 2025

can you adjust the flost switch to make the pump start at a lower water level ?

1 comments:
Mr. Anderson
February 19, 2025

The provided context does not mention the ability to adjust the float switch on the Drummond 56599 pump to start at a lower water level. It only describes maintenance and operational guidelines, including ensuring the pump sits level and keeping it free from sludge and debris. Therefore, it cannot be determined if the float switch is adjustable.

This answer is automatically generated

Peter J Lynch
April 18, 2025

The top of my pump has cracked. I am in need of the housing case. Is there any place I can purchase the upper housing case?

Summary of Contents for Drummond 56599

  • Page 1 ON/OFF OPERATION Do not return pump to the store. Call 1-844-416-9141 56599 Visit our website at: http://www.harborfreight.com Email our technical support at: productsupport@harborfreight.com When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible.
  • Page 2 This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure. Page 2 For technical questions, please call 1-888-866-5797. Item 56599...
  • Page 3: Fluid Type

    The Pump is designed for use with water at a maximum temperature of 95° F (35°C) and minimum of 32° F (0° C). Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products. Item 56599 For technical questions, please call 1-888-866-5797.
  • Page 4: Grounded Tools: Tools With Three Prong Plugs

    WARNING marking concerning Alternating Current Risk of Electric Shock. Properly connect power cord Amperes to appropriate outlet. WARNING marking concerning Risk of Eye Injury. Wear ANSI-approved safety goggles with side shields. Page 4 For technical questions, please call 1-888-866-5797. Item 56599...
  • Page 5: Power Supply

    2. This pump should NOT be used for water transfer or: Removing water from crawl spaces, window Continuous run, fountain/pond water features. wells, flat roofs, and flooded yards. Permanent basement sump systems. Septic or sewage systems. Item 56599 For technical questions, please call 1-888-866-5797. Page 5...
  • Page 6 3/4″ adapter (sold separately) to the hose. being walked on, crushed or the outlet blocked. Screw adapter to the Check Valve until tight. 3/4″ Hose 1-1/4″ Discharge Hose with 3/4″ Adapter Page 6 For technical questions, please call 1-888-866-5797. Item 56599...
  • Page 7 Do not drop the pump into a depth of more than 13’ or the automatic switch may not function properly. Be sure pump sits fully upright. Item 56599 For technical questions, please call 1-888-866-5797. Page 7...
  • Page 8 DANGER! Do not use an extension cord with this and guide the Pump towards you for removal. pump. Keep plug dry and connected to a GFCI protected outlet secured away from water. Page 8 For technical questions, please call 1-888-866-5797. Item 56599...
  • Page 9 Clean pump’s outside housing and the Switch The pump will not restart until the water Housing’s sensor/probe. Allow to dry completely. depth reaches 2" or greater. e. Store indoors out of reach of children. Item 56599 For technical questions, please call 1-888-866-5797. Page 9...
  • Page 10: Maintenance

    2. Reposition pump so it sits level on surface. 3. Dirty switch. 3. Rinse switch with clean water. Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service. Page 10 For technical questions, please call 1-888-866-5797. Item 56599...
  • Page 11 Note: If product has no serial number, record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Item 56599 For technical questions, please call 1-888-866-5797. Page 11...
  • Page 12 Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.

Table of Contents