Gas Conversions; Lp Gas Conversion - Whirlpool W10032070 User Manual

30" (76.2 cm) freestanding gas ranges
Table of Contents

Advertisement

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position.
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
12

GAS CONVERSIONS

2. Unplug range or disconnect power.
3. Open broiler door and remove broiler pan. The gas pressure
4. Remove the cap from the gas pressure regulator using a
5. Turn the cap over so the LP is visible.
6. Reinstall the cap.
B
C
regulator is located in the back right hand corner of the broiler
compartment.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
flat-blade screwdriver.
NOTE: Do not remove the spring beneath the cap.
A. Cap
A. Cap
A
A
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wfg110avWfg111svWfg110avqWfg111svqW10032070b

Table of Contents