96
Driver cockpit
Example: socket in the stowage compartment
Example: 24 V power socket
Example: AUX socket/socket
1
Cigarette lighter 5 A (max. 120 W) or 24 V
socket 15 A (max. 360 W)
2
24 V socket 15 A (max. 360 W), electric cir‐
cuit 1
3
24 V socket 15 A (max. 360 W), electric cir‐
cuit 2
4
24 V socket 15 A (max. 360 W), electric cir‐
cuit 2 or 12 V socket 15 A (180 W)
5
24 V socket 15 A (max. 360 W), electric cir‐
cuit 1
6
24 V power socket 25 A (600 W)
7
24 V power socket adapter plug
8
AUX socket (see the separate Operating
Instructions)
9
24 V socket 15 A (max. 360 W), electric cir‐
cuit 2
12 V sockets
Do not exceed a load of 180 W (15 A) for the 12 V
sockets.
Vehicles with a 12 V connection point for aux‐
iliary consumers: if you wish to use the 12 V
socket, you must switch on the voltage converter.
24 V sockets
You can use each 24 V socket for accessories up
to a maximum of 15 A (max. 360 W).
The 24 V sockets are hooked up to two electric
circuits:
Electric circuit 1: 24 V sockets
R
Electric circuit 2: 24 V sockets 3,
R
If using several 24 V sockets simultaneously in
one electric circuit, do not exceed the maximum
load of 360 W (15 A).
Vehicles without a cigarette lighter: 24 V
power socket
1
is fitted in place of the cigarette
lighter. When the ignition lock is in the radio posi‐
tion or the key has been removed, the 24 V power
socket is voltage safe.
%
To use the 24 V socket, you must switch the
ignition lock to the drive position.
24 V power socket
You can always use 24 V power socket
spective of the use of other sockets, for accesso‐
ries up to a maximum of 600 W (25 A). To use 24
V power socket 6, Mercedes-Benz recommends
that you have adapter plug
7
specialist workshop. Otherwise, safe usage can‐
not be guaranteed.
Using the 12 V voltage converter
The voltage converter supplies both the 12 V
socket and the 12 V connection point for auxiliary
consumers with a maximum of 15 A.
2
and
5
4
and
9
6
irre‐
fitted at a qualified
Need help?
Do you have a question about the Actros and is the answer not in the manual?
Questions and answers
6242 operating unit for level control has short circuit to ground
To fix a short circuit to ground in the operating unit for level control 6242 on a Mercedes-Benz Actros:
1. Inspect the wiring between the operating unit and the control module for damage or exposed wires.
2. Check the connector pins for corrosion or bending.
3. Test the circuit for continuity and isolate the shorted section.
4. Replace or repair the damaged wiring or connectors.
5. If the operating unit is faulty, replace it.
6. Clear any fault codes and test system functionality.
If the short is to positive (24V) instead of ground, follow similar steps but focus on power supply lines.
This answer is automatically generated
What affects Actross mb3 not starting,all lights on and wipers moving up and down at the same time.
My name is vignesh, my vehicle warning appeared, visit workshop energy saving mode, battery charging level warning and alternator management unavailable
Where is left side tail lamp fuse located in actros euro 6