No.
Display text
3
AKI > 60 sec. active
5
AKA > 60 sec. active
6
Unlocking error
7
No redundancy test
9
Battery fuse open
9
Open. unsuccessful
10
Locking error
11
Difference AKI
12
Low BAT voltage
12
BAT capacity
14
VAK defective
15
EMERG. OPEN.
17
Timeout open. time
18
VAK closed automatic
29
TOS not locked
30
TOS locked
31
EMERGENCY STOP
33
Error ELS1
36
VOK closed l.
37
Motor current
38
Motor 1 overheat
39
Overload 24V
41
Temp. sensor 1
42
Temp. sensor 2
43
Encoder fault
44 W
T. motor high
46
STG defective
47
SIO > 60 sec active
48
NSK or SOK activated
50
Watchdog fault
51
VOK op n unl.
52
No run param.
53
Interrupt. mot. 1
54 W
Calibrating run
55
Power failure
57
Interrupt. mot. 2
59
ELS > 60 sec. active
59
SIS > 60 sec. active
60
EEPROM defective
61
SSK > 60 sec. active
62
BDE no priority
92
STG relay defect.
93
Overvoltage 24V
96
EEPROM void
97 W
Maintenance time exceeded
98 W
Maintenance due
112
Batt. not charged complet.
2132
FPC Can blocked
*************
BDE Can blocked
*************
ERROR by saving in the STG
23
ALARM CODES AND ERROR MESSAGES
Type
Res
Comments and possible troubleshooting
Inside radar longer than 60 sec. active and door remains open. Check tt h h a e t r n a o d m a ro . ving objects are activating
Outside radar longer than 60 sec. active and door remains open. Check th ta h t e n ro a d m ao r.ving objects are activating
X
Unlocking error: it is impossible to unlock the door.
Repeat unlocking attempt after changing the BDE operating mode.
RED
X
When no „redundancy" test could happen within the last 24 h or the „redundra fo nr c m y" e t d e s o t n w aa s not correctly pe
door not locked. Reset. Control settings.
X
Battery fuse is disconnected or battery is not plugged in.
Door does not open or only slowly.
SIO might possibly be active or motion be mechanically hindered (e.g. dirt in floor track).
Locking e rr o d r e p a e n n d d d in o g o ro rn e m pa aria n m s a e p t e p rr i s o ix n.g 1 d 0o c o m r ro e p m e a n in s closed. Door might
possibly be hindered or locking device might need to be adjusted.
RED
X
Error in the interpretation of the inside radar signal. Check inside radar.
X
Battery is missing or is not plugged in. Door works if mains voltage is provided.
X
Battery no longer meets minimum power requirements. Replace Battery.
X
Locking device hampered. Adjust door leaves and locking device.
RED
On RED installations emergency opening switch has been actuated.
RED
X
80% of escape route opening not reached within 3 sec. Control with FPC, adju u s s t " ,o pening speed. Under „Stat
opening time + 400 ms.
X
Adjust locking device.
Make contact (NOC) of locking device is active with Automatic. Locking is set on „wrong" position.
Change operating mode on BDE-D to Locked and again to Automatic.
Actuate manual unlocking, or rather completely reset it.
TOS with
TOS not locked (rotary switches) on Locked. Turn rotary switches onto Locked position (above).
DV
TOS with
Automatic mode, TOS locked, but door stays in manual mode.
DV
Emergency stop key has been pressed or manual unlocking has been actuated.
X
Light barrier signal is not identified. Inform after-sales service. Calibrate ELS with 2 light pulses.
X
Locking device does not work properly. On BDE-D change operating mode to Automatic and again to Locked. Wrong
locked position or VRR faulty.
X
Possibly wrong motor type parameterised or motor is overloaded.
X
Motor 1 is too warm. Door works sluggishly.
X
24 volts supply for peripheral units is overloaded. Check wiring.
X
With motor 1: temperature sensor is faulty or motor cable is disconnected.
X
With motor 2: temperature sensor is faulty or motor cable is disconnected.
X
Encoder or cable is faulty or not plugged in. Reset.
Warning message; Time Delays will be extended.
Door might work sluggishly. Check for presence of mechanical hindrance.
X
Control unit is defective. Reset. If no success, then replace control unit.
X
Door does not open or slides at reduced speed. Check Safety Sensor SIO.
Remote Alarm has just received. Control safety alarm. Control external signal.
Replace control unit.
X
Repeat locking and unlocking procedures.
Connection cable might be missing or is not properly plugged in. Check locking settings.
X
Door must be calibrated (perform teach-in run).
X
Motor is not plugged in. Motor is faulty.
X
Warning message: Calibration run is perforned.
No mains supply. Door works in battery service provided that there is a battery and not
"Basic escape route" has been configured.
X
2nd motor is not plugged in. Motor is faulty.
Light barriers interrupted or disconnected and door remains open. Chec d k o th r at safety barriers are not covere
extremely dirty.
X
Door does not close. Check Safety Sensor SIS.
X
Load factory settings. 9 light pulses with MFT and reset within 10 seconds.t A o fb te er wards language selection has
displayed on BDE-D. Attention! All programmings are reset. Reconfigure door. Replace control unit if door still fails to
function
Key-operated contact stays active. Door remains open.
Check Remote Switch (SSK) wiring, connections, and switch.
BDE is locked e.g. by a clock timer on input SURV/SURA accordingly configured.
X
Change control unit.
X
Wiring error. Check connections.
X
Load factory settings. See error 60.
X
Warning message: Acknowledge message. Alarm is reset for 13 days. Actual v e a l o u fe c = y c 1 le 0s 5 % o r of target valu
operating hours.
Inform after-sales service and have installation serviced. Set Tar gets to 0 to avoid alert.
X
Warning message: Acknowledge message. Alarm is reset for a short time. Repeats at 100% Actual value = 95% of
target value of cycles or operating hours.
Inform after-sales service and have installation serviced. Set Tar gets to 0 to avoid alert
Battery is not fully charged. Message disappears from display in case of full charge.
On a locked door the CAN-Bus will be blocked for devices like the BDE-D(Display) or FPC if they were not connected
BEFORE the door was locked. When reading either of the 3 messages from the left column, to unblock, the door needs
to be unlocked or the emergency switch has to be activated or the multi-function switch on the control has to be pressed
for 1 flash.