Summary of Contents for CRANE PUMPS & SYSTEMS Deming 3021 Series
Page 1
Manual Index DEMING DEMING ® INSTALLATION, OPERATION & MAINTENANCE MANUAL Frame Mounted End Suction Centrifugal Pumps Series: 3021 / 3121 IMPORTANT! Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur.
SAFETY FIRST! Please Read This Before Installing Or Operating Pump. WARNING ! Do not wear loose clothing that may This information is provided for SAFETY and to PREVENT become entangled in moving parts. EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols: WARNING ! Keep clear of suction and discharge openings.
A - GENERAL INFORMATION B - INSTALLATION 1. FOUNDATION TO THE PURCHASER: The pump foundation should be suffi ciently substantial Congratulations! You are the owner of one of the fi nest to form a level, rigid support for the combined weight pumps on the market today.
NOTE: A fl exible coupling should not be used to compensate for misalignment of the pump and driver shafts. The purpose of the fl exible coupling is to compensate for temperature changes and to permit end movement of the shafts without interference with each ANGULAR other, while transmitting power from the driver to the pump.
C - OPERATION 5. PIPING The pump suction and discharge connections are not intended to indicate the required suction and discharge 1. PRIMING pipe sizes. The pipe diameter must be selected according CAUTION: Before starting the pump, the casing and to the requirements of the pumping system and suction line must be fi...
3. PUMP ADJUSTMENT 2. DISASSEMBLY - These instructions apply to the series of pumps in general and may vary slightly on some Open discharge valve as soon as operating speed has units. If complete dissembly is not necessary, use only been reached.
CAUTION - Use extreme care to prevent the 4. Pump Works For A While Then Quits shaft from hitting the seal stationary member. a. Obstruction in pump or piping Damage can result b. Air or gas in liquid c. Incomplete priming - See Priming e.
MODEL 3121 ITEM No. DESCRIPTION ITEM No. DESCRIPTION Casing *073 Casing gasket Impeller *089 Mechanical Seal Shaft Snap ring (Frame) Ring, Impeller (Optional) Name Plate (Not shown) *014 Shaft Sleeve Clip, Bearing Housing *016 Bearing (inboard) Grease Fitting *018 Bearing (outboard) Pipe Plug Frame Cap screw...
Page 10
MODEL 3021 ITEM No. DESCRIPTION ITEM No. DESCRIPTION Casing *089 Mechanical Seal Impeller Snap ring (Frame) Shaft Name Plate (Not shown) Ring, Impeller (Optional) Clip, Bearing Housing *014 Shaft Sleeve Grease Fitting *016 Bearing (inboard) Pipe Plug *018 Bearing (outboard) Cap screw Frame Drive screw...
Page 12
IMPORTANT! WARRANTY REGISTRATION Your product is covered by the enclosed Warranty. To complete the Warranty Registration Form go to: http://www.cranepumps.com/ProductRegistration/ If you have a claim under the provision of the warranty, contact your local Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”.
Page 13
A Crane Co. Company START-UP REPORT General Information Pump Owner’s Name: __________________________________________________________ Address: ____________________________________________________________________ Location of Installation: _________________________________________________________ Contact Person: __________________________________Phone: _______________________ Purchased From: _____________________________________________________________ Nameplate Data Pump Model #: ___________________ Serial #: _____________________________________ Part #: __________________________ Impeller Diameter: ____________________________ Voltage: _________ Phase: _____ Ø...
Need help?
Do you have a question about the Deming 3021 Series and is the answer not in the manual?
Questions and answers