ABB ACS880 Series User Manual page 79

Atex-certified motor thermal protection functions for cabinet-built drives
Hide thumbs Also See for ACS880 Series:
Table of Contents

Advertisement

1
2
A
WX31-X9
A
A
-X31
3
4
B
B
WK71-X31
H05V2-K
WK71-X31
1 BK
H05V2-K
1 BK
B
WK71-X31
H05V2-K
1 BK
3
4
-K71.1
PT100 RELAY
D1073S
C
mA+
mA-
13
14
15
16
1
WK71-X32
WK71-X31
H05V2-K
H05V2-K
1 BU
1 BK
WK71-X32
H05V2-K
1 BK
1
2
3
4
5
1
B
B
B
B
B
B
-X32
-X31
A
A
A
A
A
A
D
BK
BK
BK
BK
-WX32-X506
-XFE
FE1
BETAFLAM c-flex
NOTE*
NOTE*
4x1
NOTE!
BK
BK
BK
BK
WK71-X32
IF CONNECTED
H07V2-K
4 GNYE
WITH WIRES
FRAME
WIRES ARE
BK
BK
BK
BK
ON SLEEVE
=01
+01.1
FRAME
E
-X506
1
2
3
4
5
-X506
31
°t
PT-100
NOTE*= THESE EARTHINGS ARE ON SAME BUSBAR
NOTE*= THESE EARTHINGS ARE ON SAME BUSBAR
F
Cust. Doc. No.
Cust. Ref. No.
Customer
1
2
3
ATEX CERTIFIED PT-100 WINDINGS TEMPERATURE MONITORING
WK71-X31
H05V2-K
1 BK
5
7
-K71.1
//1B
6
8
WK71-A81
H05V2-K
1 BK
3
4
-K71.2
5
7
PT100 RELAY
D1073S
6
8
2
13
14
15
WK71-X32
H05V2-K
1 BU
2
7
8
9
10
B
B
B
B
-X32
A
A
A
A
BK
BK
BK
-WX32-X506
BETAFLAM c-flex
4x1
NOTE!
BK
BK
BK
IF CONNECTED
WITH WIRES
WX31-X506
H05V2-K
WIRES ARE
BK
BK
BK
1 BK
ON SLEEVE
32
-X506
6
7
8
°t
PT-100
Prep.
App.
Project
3
4
5
WK71-X31
H05V2-K
1 BK
WK71-A81
H05V2-K
5
7
1 BK
-K71.2
//3B
6
8
WK71-A81
WK71-X31
H05V2-K
H05V2-K
1 BK
1 BK
-K71.3
5
7
PT100 RELAY
D1073S
6
8
mA+
mA-
16
1
2
WK71-X31
WK71-X34
H05V2-K
H05V2-K
1 BK
1 BU
WK71-X32
H05V2-K
1 BK
6
6
7
B
B
B
B
-X31
-X34
A
A
A
A
BK
-WX34-X506
-XFE
FE2
BETAFLAM c-flex
NOTE*
NOTE*
4x1
NOTE!
BK
IF CONNECTED
WITH WIRES
WX31-X506
H05V2-K
WIRES ARE
BK
1 BK
ON SLEEVE
9
10
-X506
33
34
-X506
14.01.2020
Title
ATEX PT100 temperature monitoring
ACS880-07-0145A-3
SINGLE DRIVE
4
5
6
7
WK71-A81
H05V2-K
1 BK
5
-K71.3
//6B
6
WK71-X31
H05V2-K
1 BK
3
4
5
7
6
8
mA+
mA+
13
14
15
16
1
2
WK71-X33
H05V2-K
1 BK
WK71-X34
H05V2-K
1 BK
1
2
3
4
5
1
2
B
B
B
B
B
B
B
-X33
A
A
A
A
A
A
A
BK
BK
BK
BK
-XFE
FE3
NOTE*
NOTE*
BK
BK
BK
BK
WX33-X506
H05V2-K
BK
BK
BK
BK
1 BK
11
12
13
14
15
-X506
35
36
°t
Changes to this document shall be reviewed by
design manager and approved by Ex manager.
PT-100
Also notified body must approve the change.
( See instructions 3AFE002084 and 3AFE003559)
Circuit diagram
EFS2
SAP Doc. No.
010
EPLAN Doc. No.
ABB Ref. No.
Resp. Dept.
6
7
Circuit diagrams 79
8
A
/070b/1A
-K72.1:3
/071a/1A
-A81:A1
7
B
8
WK71-A81
H05V2-K
1 BK
/071a/1A
-A81:A2
C
D
E
SAFETY CIRCUIT
F
Item Des.
=
01
+
01.1.3
.1
070a
Rev.
Sheet
Cont.
070b
8

Hide quick links:

Advertisement

Table of Contents
loading