ABB ACS880 Series User Manual page 55

Atex-certified motor thermal protection functions for cabinet-built drives
Hide thumbs Also See for ACS880 Series:
Table of Contents

Advertisement

Configuration of
Output circuit
Kind of output
Operating principle
Contact material
Minimum switching voltage / Minimum switching current
Maximum switching voltage / Maximum switching
current
Rated operational voltage
U
and rated operational
e
current I
e
AC Rating (UL 508)
Mechanical lifetime
Electrical lifetime at AC-12, 230 V AC, 4 A
Maximum fuse rating to
achieve short-circuit
protection
General data
Duty cycle
Dimensions (Height × Width × Depth)
Weight, net
Mounting
Minimum distance to other
units
Material of housing
Degree of protection
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
11-12/14
21-22/24
AC-12 (resistive) at 230 V
AC-15 (inductive) at 230 V
DC-12 (resistive) at 24 V
DC-13 (inductive) at 24 V
Utilization category
(Control Circuit Rating
Code)
Maximum rated operational
voltage
Maximum continuous
thermal current at B 300
Maximum making/breaking
apparent power at B 300
General purpose rating
N/C contact
N/O contact
Screw connection
technology
Easy Connect Technology
(push-in)
Vertical
Horizontal
Housing
Terminals
non-volatile fault storage
short-circuit detection
disabled
Remote Test/Reset
Relay, 1st c/o (SPDT) contact
Relay, 2nd c/o (SPDT) contact
closed-circuit principle
AgNi alloy, Cd free
24 V / 10 mA
See the relay data sheet.
4 A
3 A
4 A
2 A
B 300
300 V AC
5 A
3600/360 VA
250 V AC - 4 A
6
30 x 10
switching cycles
6
0.1 x 10
switching cycles
10 A fast-acting
10 A fast-acting
100%
85.6 × 22.5 × 103.7 mm (3.37 × 0.89 × 4.08 in)
0.141 kg
0.130 kg
DIN rail (IEC/EN 60715), snap-on mounting without any
tool
10 mm (0.39 in) if switching current > 2 A
10 mm (0.39 in) if switching current > 2 A
UL 94 V-0
IP50
IP20
Technical data 55