08 - CONTROL AND SIGNALING DEVICES

01 - BOILER PRESSURE GAUGE
02 - BOARD HEATER THERMOSTAT
03 - WARNING LIGHT "UNDER
TENSION"
04 - 1st HEATED SLEEVE SHAPE
SWITCH (OPTION)
05 - SWITCH FOR 1st IRON
06 - BOILER SWITCH
07 - WARNING LIGHT "HEATER ON"
08 - WARNING LIGHT "PUMP
RUNNING"

09 - PRECAUTION

Read carefully the instructions and the risks related to the use of an ironing table. The operator has to know its
working functions and must clearly understand its dangers with the help of the manual.
If the machine features a steam iron, do not leave it switched on too long and place it always on the
relevant iron rest. The ironing boards and the soleplate of the iron remain hot for some minutes after their
switching-off, please pay therefore attention to the risks of burns and do not put objects on the table until
its complete cooling-down.
Main electrical supply
Prior to carrying out any inspection or service on the machine, it is necessary to disconnect it from the
main electrical supply. Make sure, that nobody can reconnect it during the technical service.
Every installed electrical or electronic equipment must be earthed.
Inflammability
Adopt all the necessary precautions to avoid any direct contact of the machine with hot materials or
flames. Put fire extinguishers near the machine for an immediate intervention in event of fire.
Pressure / Steam
Before each intervention, switch off the boiler first and check that there are no residual pressures inside
the boiler or in any branch of the hydraulic circuit, as they could cause steam or product spurts, in case of
disassembly of fittings or other components.
Noise
The noise emission is not excessive, because it remains under 70dB(A).

10 - INSTRUCTIONS FOR USE

PUTTING INTO OPERATION
The whole unit can be used, opened and repaired by qualified technicians only.
It is forbidden to use the machine if flooded by liquids or in particularly aggressive or
explosive/inflammable places.
Always use suitable pipes according to the working pressure.
Do not ignore the dangers for the operator's health and follow the hygienic and safety regulations.
Check that the electrical wiring is carried out correctly according to the current regulations, and that the
fuse blocks are closed and complete of fuses.
Make sure that the machine is intact.
Check that the control and safety boiler devices ( manometer, pressure switch, and safety valve) are
intact.
Make sure that the boiler discharge gate is well closed
03
02
01
6
07
05
06
04
08