  • Page 2: Preparation Before Use

    Preparation before use Before using the air conditioner, be sure to check and preset the following. Remote Controller presetting The remote controller is NOT presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer. Each time after the remote controller replaces batteries or is energized, the Cooling indicator Heating indicator will flashes alternately on LCD of the remote controller.
  • Page 3: Safety Precautions

    Safety precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure not to do. The feature of the appliance, instead of a fault. Pay attention to such a situation. Use correct power supply in accordance with the rating plate requirement.
  • Page 4: Indoor Unit

    Identification of parts Indoor unit SL EE Outdoor unit The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected. Air Intake Front Panel Emergency Panel Display Panel...
  • Page 5: Uh Series Operating/Display

    Identification of parts UH series operating and display Timer Indicator It lights up during the set time. Compressor indicator It lights up when compressor is running. The shape and position of the switches and indicators may vary from different models, but their function are similar. Run Indicator It is on during operation.
  • Page 6: Remote Controller

    Remote controller Remote controller The remote controller transmits signals to the system. ON/OFF BUTTON The appliance will be started when it is energized or will be stopped when it is in operation, if you press this button. MODE BUTTON Press this button to select the operation mode. FAN BUTTON Used to select fan speed in sequence auto, high, medium or low.
  • Page 7 Remote controller Remote controller How to Insert the Batteries Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR03 AA(1.5volt) batteries.
  • Page 8: Operation Modes

    Operation instructions Operation modes Selecting mode Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY Heating mode is NOT available for cooling only air conditioner. FAN mode Each time the "FAN" button is pressed, the fan speed is changed in sequence: Auto High...
  • Page 9: Airflow Direction Control

    Operation instructions Airflow direction control Airflow direction control Vertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. Operation mode Direction of airflow horizontal COOLING, DRY *HEATING, downward FAN ONLY *Heating mode is only available for heat pump models.
  • Page 10: 6Th Sense Mode

    Operation instructions 6th sense mode Press the button, the unit enters 6th sense mode(fuzzy logic operation) directly regardless of sense the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature. Operation mode and temperature are determined by indoor temperature Heat pump models Indoor temperature...
  • Page 11 Operation instructions Timer mode It is convenient to set the timer on with TIMER ON/OFF buttons when you go out in the morning to achieve a comfortable room temperature at the time you get home. You can also set timer off at night to enjoy a good sleep. How to set TIMER ON TIMER ON button can be used to set the timer programming as wished in order to switch on the appliance at your desired time.
  • Page 12: Sleep Mode

    Operation instructions SLEEP mode SLEEP mode SLEEP mode can be set in COOLING or HEATING operation mode. This function gives you a more comfortable environment for sleep. In SLEEP mode, The appliance will stop operation automatically after operating for 8 hours. Fan speed is automatically set at low speed.
  • Page 13 Maintenance Front panel maintenance Cut off the power supply Turn off the appliance first before disconnecting from power supply. Grasp position "a" and pull outward to remove the front panel. Wipe with a soft and dry cloth. Use lukewarm water (below 40 ) to clean if the appliance is very dirty.
  • Page 14 Protection Operating condition The protective device maybe trip and stop the appliance in the cases listed below. Outdoor air temperature is over *43 C COOLING Room temperature is below 21 C Room temperature is below 18 C If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80%,dew may drip down from the outlet.
  • Page 15: Troubleshooting

    Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Does not run No cooling or heating air Ineffective control Does not operate immediately don't run Peculiar odor A sound of flowing water Cracking sound is heard Spray mist from...
  • Page 16: Installation Instructions

    Installation instructions Installation diagram Distance from wall should be over 50mm Distance from floor should be over 2000mm Air intake distance from the wall should be over 250mm Above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased.
  • Page 17 Installation instructions Select the best location Location for Installing Indoor Unit Where there is no obstacle near the air outlet and air can be easily blown to every corner. Where piping and wall hole can be easily arranged. Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.
  • Page 18: Indoor Unit Installation

    Installation instructions Indoor unit installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. Drill holes of 32mm in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
  • Page 19 Installation instructions Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. Piping Thermal Insulation: a. Place the drain hose under the piping. b. Insulation material uses polythene foam over 6mm in thickness. Note: Drain hose is prepared by user.
  • Page 20 Installation instructions 4. Connecting of the Cable Indoor Unit Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection. Note: For some models, it is necessary to remove the cabinet to connect to indoor unit terminal.
  • Page 21 Installation instructions Wiring Diagram Make sure that the color of wires of the outdoor unit and the terminal No. are the same as those of the indoor unit. 9K,12K,18K Model COOLING ONLY Indoor unit Outdoor unit Terminal Terminal Brown Brown Blue Blue Power connecting cord...
  • Page 22: Outdoor Unit Installation

    Installation instructions Outdoor unit installation 1.Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order not to disturb your neighbor and protect the environment, install a drain port and a drain hose to direct the condensate water.
  • Page 23 Installation instructions How to Purge Air Tubes: (1). Unscrew and remove caps from 2 and 3-way valves. (2). Unscrew and remove cap from service valve. (3). Connect vacuum pump flexible hose to the service valve. (4). Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (5).