Page 1
YASKAWA AC Drive - J1000 Compact V/f Control Drive Finless Type Installation Manual Type CIMR-JJ Models 200 V Class, Three-Phase Input: 0.1 to 5.5 kW 200 V Class, Single-Phase Input: 0.1 to 2.2 kW 400 V Class, Three-Phase Input: 0.2 to 5.5 kW To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance.
Page 2
Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice.
1 Preface Preface ◆ Applicable Documentation This manual provides instructions on installing the J1000 Finless drive. For more specific information on the operation of this product, refer to the other manuals listed in the following table: Yaskawa AC Drive-J1000 Finless...
Page 5
• If nameplate becomes worn or damaged, order a replacement from your Yaskawa representative or the nearest Yaskawa sales office. • Yaskawa is not responsible for any modification of the product by the end user. Modification of the product voids the warranty.
• Verify receipt of the correct model by checking the information on the nameplate. • If you have received the wrong model or the drive does not function properly, contact your supplier. YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Page 7
Figure 1 Nameplate Information Drive Model Identification ■ The J1000 finless drive type is indicated by the letter “J” in the AC drive model designation code. Refer to the Quick Start Guide for complete model number information. Figure 2 A 0 0 0 1 J...
Name Description 00408 H4-01 Analog Output Terminal AM Function Selection (heatsink plate temperature) H4-02 Analog Output Terminal AM Gain 100.0% H4-03 Analog Output Terminal AM Bias 0.0% YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Page 9
When applying the thermal compound, spread it over the surface of the heatsink plate. After mounting the heatsink plate to the metal back panel, wipe away any excess compound from around the heatsink plate. YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Page 10
1.0 to 1.3 (0.74 to 0.96) NOTICE: Tighten all screws according to specified torques. Failure to do so may inhibit drive cooling and possible damage the drive. YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Page 11
NOTICE: Do not install J1000 Finless drives using the Side-by-Side method available in standard J1000 drive models. Improper drive cooling may result in damage to the drive. Install J1000 Finless drives with a minimum side-by-side clearance of 30 mm (1.18 in).
Page 12
Parameter L8-12 = 30°C (default). The setting range is -10 to 50°C. Operating the J1000 Finless drive between -10 and 35 ºC allows 100% continuous current without derating. Drive operation between 35 and 50 ºC requires drive derating according to Figure The drive can be used with 100% rating between -10 and 50°C ambient temperature if the...
Page 13
13.9 16.8 21.8 28.5 31.4 46.0 – – Total (W) 19.6 32.4 47.3 66.3 87.0 95.1 127.7 – – Note: Carrier frequency is set to 2 kHz. YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Page 14
Total (W) 30.6 43.8 60.2 96.9 111.7 117.5 148.7 – – <1> Carrier frequency is set to 10 kHZ. <2> Carrier frequency is set to 8 kHZ. YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
• Load factor: 80% max. • Operation time: 12 hours a day Drive performance life may be less than 10 years if drive use exceeds the conditions above. YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
6 Selecting an External Heatsink Selecting an External Heatsink This section describes the selection of a suitable external heatsink when using a J1000 Finless drive. ◆ Data Required for Heatsink Selection The table below shows data that are needed to select a heatsink that suits drive and application.
Page 21
If a heatsink is given or the selection is limited by the installation conditions (space available etc.) use the formula below to calculate the actual heatsink plate temperature. Rθ + Rθ + Rθ ) + T Loss HSP-EHS YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Page 23
(reduced heatsink cooling ability by dirt, etc.), a heatsink with a lower Rθ (e.g. Rθ = 1.1 K/W, resulting in T = 72.2ºC) should be chosen. YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Published in Japan August 2008 08-8 Date of original Date of publication publication Date of Rev. No. Section Revised Content Publication − − August 2008 First edition YASKAWA ELECTRIC TOBP C710606 40A YASKAWA AC Drive - J1000 Finless Installation Manual...
Page 25
No.18 Xizang Zhong Road. Room 1702-1707, Harbour Ring Plaza Shanghai 200001, China Phone 86-21-5385-2200 Fax 86-21-5385-3299 YASKAWA ELECTRIC (SHANGHAI) CO., LTD. BEIJING OFFICE Room 1011A, Tower W3 Oriental Plaza, No.1 East Chang An Ave., Dong Cheng District, Beijing 100738, China...
Need help?
Do you have a question about the J1000 and is the answer not in the manual?
Questions and answers