Huawei SUN2000 Series Quick Manual page 11

Hide thumbs Also See for SUN2000 Series:
Table of Contents

Advertisement

There are two types of Smart Dongle involved in this document:
WLAN-FE Smart Dongle: SDongleA-05
4G Smart Dongle: SDongleA-03
For details, see the quick guide that is delivered with the Smart Dongle. You can scan the QR code
to obtain it.
3.6
(Optional) Installing the Signal Cable
Not all inverter models are delivered with the
signal cable connector.
When laying out the signal cable, separate it
from the power cable and keep it away from
strong interference sources to avoid strong
communication interference.
Ensure that the protection layer of the cable is
inside the connector, surplus core wires are
cut off from the protection layer, the exposed
core wire is totally inserted into the cable hole,
and that the cable is connected securely.
If the Smart Dongle is configured, you are
advised to install the Smart Dongle before
connecting the signal cable.
Pin Definition Function
RS485
1
485A1-1
differential
signal+
3
485B1-1
RS485
differential
signal–
Shielding
5
PE
ground
7
485A2
RS485
differential
signal+
9
485B2
RS485
differential
signal–
11 N/A
N/A
13 GND
GND
15 N/A
N/A
WLAN-FE
Description
Used to cascade
inverters or connect
to the RS485 signal
port on the
SmartLogger1000A
N/A
Used to connect to
an RS485 signal
port on a Smart
Power Sensor for
export limitation
N/A
N/A
N/A
4G
Communications Port Pin Definition
Pin Definition Function
RS485
2
485A1-2
differential
signal+
4
485B1-2
RS485
differential
signal–
Shielding
6
PE
ground
8
Dry
DIN1
contact
interface
for grid
10
scheduling
DIN2
12
DIN3
14
DIN4
16
GND
10
Description
Used to cascade
inverters or
connect to the
RS485 signal port
on the
SmartLogger1000A
N/A
Connect to ripple
control receiver.
For details, see the
user manual.

Advertisement