TROUBLE SHOOTING
A.
High gauge pressure, low return flow.
1.
Filter requires backwashing.
2.
Or, excessive contaminants or algae coated
on "V" grids inside filter. Backwash to
correct.
3.
Calcium crustation in "V" grid cloth.
Disassemble filter and wash grids with 1 part
muriatic acid to 4 parts water.
B.
Low gauge pressure, low flow. Pump
suction is drawing in air (noted by
bubbles returning to pool), or pump
sounds like marbles are rattling in it.
1.
Pool water level is too low. SWITCH PUMP
"OFF" AT ONCE. Fill pool so water level is
between markers on skimmer faceplate.
2.
Or, there is a restriction on the suction side
of the pump.
3.
Or, pump strainer assembly is clogged with
debris. Clean strainer assembly.
4.
Or, tighten pump strainer assembly lid.
C.
High flow, low or normal gauge
pressure...but pool water won't clear up.
1.
Pool water is chemically out of balance. Use
water test kit to check balance.
2.
Or, opening in "V" grid cloth.
3.
Or, "V" grid assembly inside filter is loose
and by-passing water.
D.
Very short filtering cycles.
1.
Excessive suspended contaminants or algae
in pool water. (Filter will require frequent
backwashing until pool clears up.)
ITEM
P/N
365-1919
1
—
2
3
376-1050
4
327-1007
5
330-1025
6
1121-1521
7
395-1014
8
308-1039
9
340-1224
10
327-1006
11
396-1023
12
308-1044
13
340-2229
14
340-2228
15
307-1022
16
324-1020
17
340-1299
18
307-1001
19
340-1035
20
340-1225
* NOTE: Item 21 includes items 15 and 35.
SEQUEL II
QTY
DESCRIPTION
1
Owner's Guide
1
Warranty Card
1
Pin, Valve Handle
2
Friction Washer - Delrin
6
#12 x 1 1/8" Screw
1
Valve Cover Assembly
1
Pressure Gauge
3
O-Ring, Hose Adaptor
1
Hose Adaptor - Light Oak
2
Valve Bearing Washer - S.S.
1
Spring, Valve Rotor
1
O-Ring, Valve Rotor
1
Valve Rotor
1
Valve Handle
1
Gasket, Rotor Valve
18
1/4" Flange Bolt
1
Waste Port Adaptor
1
Gasket (Drain Cap)
1
Drain Cap
1
Hose Adaptor - Almond
2.
Calcium crustration in "V" grid cloth.
Disassemble filter and wash grids in 1 part
muriatic acid to 4 parts water.
E.
Cloudy puff coming out of return fitting.
1.
Place valve handle in FILTER TO WASTE
position when turning on pump and during
precoating of D.E..
2.
Or, if vacuuming, place valve handle in
PUMP TO WASTE position.
F.
Water is leaking to waste.
1.
Inspect drain cap (19) and gasket (18) for
needed repair.
2.
Actuate and rotate valve handle to clear
seating area of debris.
3.
Or, replace valve gasket in tank cover.
G.
Filter is backwashing when valve handle
is in FILTER position after servicing filter.
1.
Valve cover is assembled backwards on tank
cover (180
During disassembly of the filter, mark each part's
assembled position as it relates to the mating part to
assure proper alignment when reassembled.
Malfunctioning of the filter will occur if not properly
reassembled. Use only original Doughboy replacement
parts. See your professional Doughboy pool dealer for
Original Equipment Manufactured (OEM) parts and
servicing.
PARTS LIST
- MODEL 0-1651-000
TM
ITEM
P/N
*21
1116-1172
22
308-1114
23
308-1084
24
330-1024
25
1107-1097
26
1111-1012
27
340-1199
28
340-1200
29
340-1180
30
321-1021
31
340-1183
32
308-1043
33
346-1013-1
34
387-1017
35
343-1100
36
346-1035-1
37
326-1008
38
360-1397
6
o
from correct position).
SERVICE
QTY
DESCRIPTION
1
Tank Cover Assembly
1
O-Ring, Tank
1
O-Ring
4
#12 x 3/4" Phillips Screws
1
Grid Collector
8
"V" Grid Assembly
1
"V" Grid Assembly Base
1
Riser Nut
1
16" Dia. Molded Tank
18
1/4" - 20 Hex Nut
1
Plug, Tank Drain
1
O-Ring, Tank Drain
1
Hose, 1 1/2" x 2 1/2' Lg.
6
Wire Hose Clamp - 1 1/2"
1
Air Relief
2
Hose, 1 1/2" x 8' Lg.
18
1/4" Washer
1
Operating Instruct. Decal
Need help?
Do you have a question about the Sequel II 0-1651-000 and is the answer not in the manual?
Questions and answers